바이패스유로 멀티사이클을 적용한 냉동시스템의 성능특성에 관한 연구
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김기열 | - |
dc.contributor.author | 정해원 | - |
dc.contributor.author | 김용찬 | - |
dc.date.accessioned | 2021-09-08T23:03:37Z | - |
dc.date.available | 2021-09-08T23:03:37Z | - |
dc.date.created | 2021-06-17 | - |
dc.date.issued | 2009 | - |
dc.identifier.issn | 1229-6422 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/121448 | - |
dc.description.abstract | The purpose of this study is to investigate the performance characteristics of a bypass two-circuit refrigerator. A bench scale refrigeration system was designed and constructed to estimate possible performance improvement of the bypass two-circuit refrigerator. The experiments were conducted in the bench scale refrigeration system by varying capacity of the condenser and refrigerant charge amount with an adoption of a refrigerant storage vessel. The COPs of the bypass two-circuit refrigeration system in the refrigerator and freezer (RF)-mode and freezer(F) only-mode were increased by 10% and 17%, respectively, with increasing the capacity of the condenser. Besides, the COP of the system in the F only-mode was increased by 10% by adopting the refrigerant storage vessel. | - |
dc.language | Korean | - |
dc.language.iso | ko | - |
dc.publisher | 대한설비공학회 | - |
dc.title | 바이패스유로 멀티사이클을 적용한 냉동시스템의 성능특성에 관한 연구 | - |
dc.title.alternative | Performance Characteristics of a Bypass Two-Circuit Refrigeration System | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 김용찬 | - |
dc.identifier.bibliographicCitation | 설비공학 논문집, v.21, no.6, pp.319 - 325 | - |
dc.relation.isPartOf | 설비공학 논문집 | - |
dc.citation.title | 설비공학 논문집 | - |
dc.citation.volume | 21 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 319 | - |
dc.citation.endPage | 325 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART001348741 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Bypass two-circuit cycle(바이패스유로 멀티사이클) | - |
dc.subject.keywordAuthor | Refrigerant charge(냉매충전량) | - |
dc.subject.keywordAuthor | COP(성능계수) | - |
dc.subject.keywordAuthor | Refrigerator(냉장고) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.