Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

비침습적 산소 및 이산화탄소 분압의 감시 - 경피적 산소 및 이산화탄소 분압과 호기말 이산화탄소 분압 측정의 정확도 -

Full metadata record
DC Field Value Language
dc.contributor.author정동민-
dc.contributor.author문성우-
dc.contributor.author최성혁-
dc.contributor.author홍윤식-
dc.contributor.author이성우-
dc.contributor.author임성익-
dc.contributor.author윤영훈-
dc.date.accessioned2021-09-08T23:08:38Z-
dc.date.available2021-09-08T23:08:38Z-
dc.date.created2021-06-17-
dc.date.issued2009-
dc.identifier.issn1226-4334-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/121478-
dc.description.abstractPurpose: To determine the concordance of transcutaneous CO₂ (PtcCO₂) versus arterial CO₂ (PaCO₂), end-tidal CO₂ (PetCO₂) versus PaCO₂, and transcutaneous O₂ (PtcO₂) versus arterial O₂ (PaCO₂) among healthy adult volunteers, and to determine the normal values of the PtcCO₂/PtcO₂ and PtcO₂/PaO₂ that will be used as early signs of shock or as prognostic factors for critically ill patients. Methods: We measured the PtcO₂, PtcCO₂, PetCO₂, PaO₂, and PaCO₂ from 11 healthy volunteers while breathing room air or O₂ at a flow rate of 6 L/min via nasal cannula. The PtcO₂ and PtcCO₂ were measured using a Radiometer’'s transcutaneous sensor that interfaced with the Solar 8000 patient monitor system. The PetCO₂ was measured using a side stream capnometer that sampled air from a nasal catheter. The PaO₂ and PaCO₂ were measured from arterial blood samples. The concordances of the PtcCO₂ versus the PaCO₂, the PtcO₂ versus the PaO₂, and the PetCO₂ versus the PaCO₂ were analyzed using a Bland-Altman plot. We defined the normal values of the P(a-tc)CO₂, PtcO₂/PaO₂, and PtcCO₂/PtcO₂. Results: Twenty-two pairs of the PtcCO₂ versus PaCO₂, PtcO₂ versus PaO₂, and PetCO₂ versus PaCO₂ were obtained. The mean (±SD) values of the P(a-tc)CO₂, P(atc) O₂, and P(a-et)CO₂ were 0(±2.2) mmHg, 35.4(±24.1) mmHg, and 1.4(±1.3) mmHg, respectively (p=0.947, p<0.001, and p<0.001 by paired t-test, respectively). The P(a-tc)CO₂ and P(a-et)CO₂ showed a high concordance of 95.5% within a range of ±4 mmHg. The median (25~75%) values of the PtcCO₂/PtcO₂ and PtcO₂/PaO₂ at room air were 54.8%(46.8%~6₂.7%), respectively. Conclusion: The PtcCO₂ and PetCO₂ had a reliable concordance with the PaCO₂. However, the PtcO₂ was discordant with the PaO₂ and this discordance was increased when inspiring O₂. Therefore, the absolute values of the PtcO₂ cannot be used as a surrogate measurement of the PaO₂. However, because the O₂ supply did not increase the PtcCO₂, but rather the PtcO₂, we can use the trend in the change in the PtcCO₂/PtcO₂ or PtcO₂/PaO₂ in shock patients-
dc.languageKorean-
dc.language.isoko-
dc.publisher대한응급의학회-
dc.title비침습적 산소 및 이산화탄소 분압의 감시 - 경피적 산소 및 이산화탄소 분압과 호기말 이산화탄소 분압 측정의 정확도 --
dc.title.alternativeNon-invasive Monitoring of Oxygen and Carbon Dioxide Tension - Accuracy of Transcutaneous O₂ and CO₂ and Endtidal CO₂ --
dc.typeArticle-
dc.contributor.affiliatedAuthor문성우-
dc.contributor.affiliatedAuthor최성혁-
dc.contributor.affiliatedAuthor홍윤식-
dc.contributor.affiliatedAuthor이성우-
dc.identifier.bibliographicCitation대한응급의학회지, v.20, no.5, pp.481 - 487-
dc.relation.isPartOf대한응급의학회지-
dc.citation.title대한응급의학회지-
dc.citation.volume20-
dc.citation.number5-
dc.citation.startPage481-
dc.citation.endPage487-
dc.type.rimsART-
dc.identifier.kciidART001388655-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorTranscutaneous oximetry-
dc.subject.keywordAuthorTranscutaneous capnometry-
dc.subject.keywordAuthorCapnometry-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Sung Woo photo

Lee, Sung Woo
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE