수치해석을 통한 수직 밀폐형 지중열교환기 단면의 열전달 효율 분석
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 길후정 | - |
dc.contributor.author | 이강자 | - |
dc.contributor.author | 이철호 | - |
dc.contributor.author | 최항석 | - |
dc.date.accessioned | 2021-09-08T23:37:32Z | - |
dc.date.available | 2021-09-08T23:37:32Z | - |
dc.date.created | 2021-06-17 | - |
dc.date.issued | 2009 | - |
dc.identifier.issn | 1229-2427 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/121632 | - |
dc.description.abstract | This paper presents a series of numerical simulations on the thermal performance and sectional efficiency of a closed-loop vertical ground heat exchanger (U-loop) in a geothermal heat pump system (GHP). A 2-D finite element analysis adopting ANSYS was employed to evaluate the temperature distribution over the cross section of the U-loop system involving HDPE pipe/grout/soil to compare the sectional efficiency between the conventional U-loop and a new latticed HDPE pipe system, which is equipped with a thermally insulating lattice in order to reduce thermal interference from the inlet pipe to outlet pipe. In addition, a 3-D finite volume analysis (FLUENT) was used in simulating the operation of the closed-loop vertical ground heat exchanger with the consideration of the effect of grout’s thermal properties, the rate of circulation pump, the distance between the inlet and outlet pipes, and the effectiveness of the latticed HDPE pipe system. It was observed that the thermal interference between the two strands of U-loop is of importance in determining the efficiency of the ground heat exchanger. Therefore, it is highly recommended to modify the configuration of the conventional U-loop system by equipping the thermal insulating lattice between the two pipe strands. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | 한국지반공학회 | - |
dc.title | 수치해석을 통한 수직 밀폐형 지중열교환기 단면의 열전달 효율 분석 | - |
dc.title.alternative | Numerical Evaluation on Thermal Performance and Sectional Efficiency of Closed-Loop Vertical Ground Heat Exchanger | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 최항석 | - |
dc.identifier.bibliographicCitation | 한국지반공학회논문집, v.25, no.3, pp.57 - 64 | - |
dc.relation.isPartOf | 한국지반공학회논문집 | - |
dc.citation.title | 한국지반공학회논문집 | - |
dc.citation.volume | 25 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 57 | - |
dc.citation.endPage | 64 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART001336332 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Ground heat exchanger | - |
dc.subject.keywordAuthor | HDPE pipe | - |
dc.subject.keywordAuthor | Latticed pipe | - |
dc.subject.keywordAuthor | Sectional efficiency | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.