Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A comparison of the implant stability among various implant systems: Clinical study

Full metadata record
DC Field Value Language
dc.contributor.authorKim, J.-M.-
dc.contributor.authorKim, S.-J.-
dc.contributor.authorHan, I.-
dc.contributor.authorShin, S.-W.-
dc.contributor.authorRyu, J.-J.-
dc.date.accessioned2021-09-09T00:29:47Z-
dc.date.available2021-09-09T00:29:47Z-
dc.date.created2021-06-17-
dc.date.issued2009-
dc.identifier.issn2005-7806-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/121915-
dc.description.abstractTo determine the change in stability of single-stage, three different design of implant systems in humans utilizing resonance frequency analysis for early healing period (24 weeks), without loading. MATERIAL AND METHODS. Twenty-five patients were included into this study. A total of 45 implants, three different design of implant systems (group A,C,R) were placed in the posterior maxilla or mandible. The specific transducer for each implant system was used. ISQ (implant stability quotient) reading were obtained for each implant at the time of surgery, 3, 6, 8, 10, 12, 24 weeks postoperatively. Data were analyzed for different implant type, bone type, healing time, anatomical locations. RESULTS. For each implant system, a two-factor mixed-model ANOVA demonstrated that a significant effect on ISQ values (group A = 0.0022, C = 0.017, R = 0.0018). For each implant system, in a two-factor mixed model ANOVA, and two-sample t-test, the main effect of jaw position (P > .005) on ISQ values were not significant. CONCLUSIONS. All the implant groups A, C and R, the change patterns of ISQ over time differed by bone type. Implant stability increased greatly between week 0 and week six and showed slow increase between week six and six months (plateau effect). © 2009 The Korean Academy of Prosthodontics.-
dc.languageEnglish-
dc.language.isoen-
dc.titleA comparison of the implant stability among various implant systems: Clinical study-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, S.-J.-
dc.contributor.affiliatedAuthorShin, S.-W.-
dc.contributor.affiliatedAuthorRyu, J.-J.-
dc.identifier.doi10.4047/jap.2009.1.1.31-
dc.identifier.scopusid2-s2.0-84873249588-
dc.identifier.bibliographicCitationJournal of Advanced Prosthodontics, v.1, no.1, pp.31 - 36-
dc.relation.isPartOfJournal of Advanced Prosthodontics-
dc.citation.titleJournal of Advanced Prosthodontics-
dc.citation.volume1-
dc.citation.number1-
dc.citation.startPage31-
dc.citation.endPage36-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART001327392-
dc.description.journalClass1-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.description.journalRegisteredClassother-
dc.subject.keywordAuthorBone quality type-
dc.subject.keywordAuthorImplant stability-
dc.subject.keywordAuthorMagnetic resonance frequency analysis-
dc.subject.keywordAuthorOsseointegration-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ryu, Jae Jun photo

Ryu, Jae Jun
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE