The development of a diagnostic reference level on patient dose for CT examination in Korea

Full metadata record
DC Field Value Language
dc.contributor.authorCho, PyongKon-
dc.contributor.authorSeo, BoKyung-
dc.contributor.authorChoi, TaeKyu-
dc.contributor.authorKim, JangSeob-
dc.contributor.authorKim, YouHyun-
dc.contributor.authorChoi, JongHak-
dc.contributor.authorOh, YuWhan-
dc.contributor.authorKim, KiHyun-
dc.contributor.authorKim, SunUng-
dc.date.accessioned2021-09-09T08:56:08Z-
dc.date.available2021-09-09T08:56:08Z-
dc.date.created2021-06-10-
dc.date.issued2008-05-
dc.identifier.issn0144-8420-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/123661-
dc.description.abstractThe purpose of this research is to develop a diagnostic reference level for computed tomography (CT) suitable for Korean medical purposes. The direction of CT application and details on patient dose were investigated by survey, and the dose measurement is targeted in general hospitals registered with the Korean Hospital Association. The dose measurement was done with head and body phantom, and an accurate dosimeter was utilised in medical institutions that participated in the survey. The survey and dose measurements on the patient dose showed that the 75th percentiles in the distribution of weighted CT dose index (CTDIw) were 50.5 and 45.4 mGy for the head and 14.4 and 25.30 mGy for the body portions, respectively. Based on these research data, the target patient doses that are believed to be achievable for CT examination in Korean circumstances are about 48 +/- 4 mGy in the head and 20 +/- 8 mGy in the body.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherOXFORD UNIV PRESS-
dc.titleThe development of a diagnostic reference level on patient dose for CT examination in Korea-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, YouHyun-
dc.contributor.affiliatedAuthorChoi, JongHak-
dc.contributor.affiliatedAuthorKim, SunUng-
dc.identifier.doi10.1093/rpd/ncm463-
dc.identifier.scopusid2-s2.0-49249108492-
dc.identifier.wosid000258144400017-
dc.identifier.bibliographicCitationRADIATION PROTECTION DOSIMETRY, v.129, no.4, pp.463 - 468-
dc.relation.isPartOfRADIATION PROTECTION DOSIMETRY-
dc.citation.titleRADIATION PROTECTION DOSIMETRY-
dc.citation.volume129-
dc.citation.number4-
dc.citation.startPage463-
dc.citation.endPage468-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEnvironmental Sciences & Ecology-
dc.relation.journalResearchAreaPublic, Environmental & Occupational Health-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryEnvironmental Sciences-
dc.relation.journalWebOfScienceCategoryPublic, Environmental & Occupational Health-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Department of Radiologic Science > 1. Journal Articles
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles
College of Science and Technology > Semiconductor Physics in Division of Display and Semiconductor Physics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE