Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of a new polytetrafluoroethylene-covered metallic stent to a noncovered stent in canine ureters

Authors
Chung, Hwan-HoonLee, Seung HwaCho, Sung BumPark, Hong SukKim, Young SikKang, Byung ChulFrisoli, Joan K.Razavi, Mahmood K.
Issue Date
5월-2008
Publisher
SPRINGER
Keywords
ureter; interventional procedures; experimental study
Citation
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, v.31, no.3, pp.619 - 628
Indexed
SCIE
SCOPUS
Journal Title
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY
Volume
31
Number
3
Start Page
619
End Page
628
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/123688
DOI
10.1007/s00270-007-9087-5
ISSN
0174-1551
Abstract
The aim of this study was to determine the feasibility of using a newly designed polytetrafluoroethylene (PTFE)-covered metallic stent in the ureter by comparing its effectiveness with that of the noncovered stent in a canine model. We placed 14 stents in the ureters of seven mongrel dogs that weighed 30-40 kg each. The covered and noncovered stents were deployed in the right and left ureters, respectively, of six dogs. In the seventh dog, a covered stent and a double-J catheter were inserted in the right ureter, and a covered stent only was inserted in the left ureter. The first six dogs were sacrificed at 5, 10, and 15 weeks after deployment of the stents (two for each follow-up period), and the seventh dog was sacrificed at 30 weeks. There was no migration or poor expansion of any of the stents observed on plain radiography. On intravenous pyelogram and retrograde pyelogram, all of the covered stents at each follow-up period had patent lumens at the stented segments without hydronephrosis, and the passage of contrast material through it was well preserved. The noncovered stents in the dogs sacrificed at 5 and 10 weeks and one of the two dogs sacrificed at 15 weeks showed near-complete occlusion of the stent lumen due to ingrowth of the soft tissue, and severe hydronephrosis was also noted. The noncovered stent in the other dog sacrificed at 15 weeks showed the passage of contrast material without hydronephrosis, but the lumen of the stent was still nearly occluded by the soft tissue. There was no evidence of hydronephrosis or passage disturbance of the contrast material in both ureters of the dog sacrificed at 30 weeks. We conclude that the newly designed PTFE-covered stent effectively prevented the luminal occlusion caused by urothelial hyperplasia compared to the near-total occlusion of the noncovered stents, and no migration of the covered stents was noted.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Young Sik photo

Kim, Young Sik
의과학과
Read more

Altmetrics

Total Views & Downloads

BROWSE