Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Effects of flash gas generation at the expansion device inlet on the dynamic characteristics of a refrigeration system

Full metadata record
DC Field Value Language
dc.contributor.authorKang, Hoon-
dc.contributor.authorJoo, Youngju-
dc.contributor.authorKim, Yonchan-
dc.date.accessioned2021-09-09T09:06:24Z-
dc.date.available2021-09-09T09:06:24Z-
dc.date.created2021-06-10-
dc.date.issued2008-05-
dc.identifier.issn0140-7007-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/123690-
dc.description.abstractThe flash gas generation at the expansion device inlet in multi-air-conditioners causes rapid reduction of refrigerant mass flow rate and irregular distribution of refrigerant into multi-indoor units. The objective of this study is to evaluate the influence of the flash gas generation on the dynamic characteristics of a refrigeration system. The dynamic characteristics of a refrigeration system with an electronic expansion valve (EEV) were measured with time at various levels of flash gas generation, which were expressed as flash gas ratio. In addition, the averaged operating parameters and system COP were investigated with the variation of flash gas ratio. As the EEV inlet condition changed from the subcooled to the two-phase state, the refrigerant flow rate decreased rapidly due to the flash gas generation at the EEV inlet. At two-phase inlet conditions, the system operating parameters, such as mass flow rate, suction and discharge pressures, fluctuated periodically with time. As the flash gas ratio increased, the average COP decreased and the discharge temperature increased, degrading the system performance and reliability more severely. (C) 2007 Elsevier Ltd and IIR. All rights reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherELSEVIER SCI LTD-
dc.subjectSHORT TUBE ORIFICES-
dc.subject2-PHASE FLOW-
dc.subjectHEAT-EXCHANGERS-
dc.subjectPERFORMANCE-
dc.titleEffects of flash gas generation at the expansion device inlet on the dynamic characteristics of a refrigeration system-
dc.typeArticle-
dc.contributor.affiliatedAuthorKang, Hoon-
dc.contributor.affiliatedAuthorKim, Yonchan-
dc.identifier.doi10.1016/j.ijrefrig.2007.08.005-
dc.identifier.scopusid2-s2.0-40049098656-
dc.identifier.wosid000254677900006-
dc.identifier.bibliographicCitationINTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, v.31, no.3, pp.396 - 403-
dc.relation.isPartOfINTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID-
dc.citation.titleINTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID-
dc.citation.volume31-
dc.citation.number3-
dc.citation.startPage396-
dc.citation.endPage403-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaThermodynamics-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryThermodynamics-
dc.relation.journalWebOfScienceCategoryEngineering, Mechanical-
dc.subject.keywordPlusSHORT TUBE ORIFICES-
dc.subject.keywordPlus2-PHASE FLOW-
dc.subject.keywordPlusHEAT-EXCHANGERS-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordAuthorrefrigeration system-
dc.subject.keywordAuthorelectronic expansion device-
dc.subject.keywordAuthorsurvey-
dc.subject.keywordAuthorperformance-
dc.subject.keywordAuthorparameter-
dc.subject.keywordAuthortwo-phase flow-
dc.subject.keywordAuthorgas-
dc.subject.keywordAuthorexpansion-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher KIM, Yong Chan photo

KIM, Yong Chan
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE