Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of hemolytic properties of different shapes of occlusion of blood sac in occlusive-type pulsatile blood pump

Full metadata record
DC Field Value Language
dc.contributor.authorChoi, Hyuk-
dc.contributor.authorMin, Byoung Goo-
dc.contributor.authorWon, Yong Soon-
dc.date.accessioned2021-09-09T11:45:37Z-
dc.date.available2021-09-09T11:45:37Z-
dc.date.created2021-06-10-
dc.date.issued2008-02-
dc.identifier.issn0160-564X-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/124197-
dc.description.abstractThe occlusive-type pulsatile extracorporeal blood pump (T-PLS, Seoul National University, Seoul, Korea) received the Communaute Europeenne mark of the European Directives (2003) and Korea Food and Drug Administration approval (2004) for short-term application as an extracorporeal life support system. The pump system was recently upgraded in the ameliorated actuator head for reducing hemolysis, rather than in the existing actuator head. In this study, the hemolytic performance of the new pump system (assessed as the degree of occlusiveness of the blood sac) was compared with the existing one. A roller pump, the Stockert S3 (Stockert Instrumente GmbH, Munchen, Germany), was selected as a control device. Five tests were conducted for each pump, with each of these tests lasting for 6 h. A pump flow of 3 L/min with 50 beats per minute was included in the hemolytic test conditions. The lowest hemolytic results were obtained by the new pump system yielding a normalized index of hemolysis of less than 0.005 g/100 L, and this result was one-fourth that of the roller pump, Stockert S3.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherWILEY-
dc.subjectTOTAL ARTIFICIAL-HEART-
dc.subjectNONPULSATILE PERFUSION-
dc.subjectCENTRIFUGAL PUMPS-
dc.subjectFLOW-
dc.subjectSUPPORT-
dc.subjectCIRCULATION-
dc.subjectECLS-
dc.titleComparison of hemolytic properties of different shapes of occlusion of blood sac in occlusive-type pulsatile blood pump-
dc.typeArticle-
dc.contributor.affiliatedAuthorChoi, Hyuk-
dc.identifier.doi10.1111/j.1525-1594.2007.00529.x-
dc.identifier.scopusid2-s2.0-38849140180-
dc.identifier.wosid000252964700010-
dc.identifier.bibliographicCitationARTIFICIAL ORGANS, v.32, no.2, pp.160 - 166-
dc.relation.isPartOfARTIFICIAL ORGANS-
dc.citation.titleARTIFICIAL ORGANS-
dc.citation.volume32-
dc.citation.number2-
dc.citation.startPage160-
dc.citation.endPage166-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaTransplantation-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.relation.journalWebOfScienceCategoryTransplantation-
dc.subject.keywordPlusTOTAL ARTIFICIAL-HEART-
dc.subject.keywordPlusNONPULSATILE PERFUSION-
dc.subject.keywordPlusCENTRIFUGAL PUMPS-
dc.subject.keywordPlusFLOW-
dc.subject.keywordPlusSUPPORT-
dc.subject.keywordPlusCIRCULATION-
dc.subject.keywordPlusECLS-
dc.subject.keywordAuthorocclusive-type pulsatile blood pump-
dc.subject.keywordAuthoractuator head design-
dc.subject.keywordAuthorhemolysis testing-
dc.subject.keywordAuthordegree of occlusiveness of the blood sac-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Choi, Hyuk photo

Choi, Hyuk
의과학과
Read more

Altmetrics

Total Views & Downloads

BROWSE