냉방주체 운전모드에서 동시냉난방 열펌프 성능향상에 관한 실험적 연구
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 정현준 | - |
dc.contributor.author | 주영주 | - |
dc.contributor.author | 강훈 | - |
dc.contributor.author | 김용찬 | - |
dc.contributor.author | 최종민 | - |
dc.date.accessioned | 2021-09-09T14:15:22Z | - |
dc.date.available | 2021-09-09T14:15:22Z | - |
dc.date.created | 2021-06-17 | - |
dc.date.issued | 2008 | - |
dc.identifier.issn | 1229-6422 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/124851 | - |
dc.description.abstract | The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the improved wall insulation. Hence, a multi-heat pump is required to cover heating and cooling simultaneously for each indoor unit. In this study, the operating characteristics and performance of a simultaneous heating and cooling heat pump in the cooling-main operating mode were investigated experimentally.The system adopted a variable speed compressor using R410A with four indoor units and one outdoor unit. In the cooling-main mode, the heating capacity decreased due to reduction of flow rate to the indoor unit under heating mode operation. The EEV opening was adjusted to increase flow rate to the indoor unit under heating mode operation. The total capacity and COP in the cooling-main mode increased by 20.5% and 29.2%, respectively, compared with those in the cooling-only mode | - |
dc.language | Korean | - |
dc.language.iso | ko | - |
dc.publisher | 대한설비공학회 | - |
dc.title | 냉방주체 운전모드에서 동시냉난방 열펌프 성능향상에 관한 실험적 연구 | - |
dc.title.alternative | Experimental Study on the Performance Improvement of a Simultaneous Heating and Cooling Heat Pump in the Cooling-main Operating Mode | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 김용찬 | - |
dc.identifier.bibliographicCitation | 설비공학 논문집, v.20, no.5, pp.314 - 320 | - |
dc.relation.isPartOf | 설비공학 논문집 | - |
dc.citation.title | 설비공학 논문집 | - |
dc.citation.volume | 20 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 314 | - |
dc.citation.endPage | 320 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART001243800 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Simultaneous heating and cooling(동시냉난방) | - |
dc.subject.keywordAuthor | Heat pump(열펌프) | - |
dc.subject.keywordAuthor | Heat recovery (열회수) | - |
dc.subject.keywordAuthor | Operating mode(운전모드) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.