Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

중증 뇌손상 환자에게 비침습적 과호흡 감시로서 호기말 이산화탄소의 이용

Full metadata record
DC Field Value Language
dc.contributor.author한철-
dc.contributor.author홍윤식-
dc.contributor.author정동민-
dc.contributor.author이선범-
dc.contributor.author최성혁-
dc.contributor.author문성우-
dc.contributor.author이성우-
dc.date.accessioned2021-09-09T14:36:07Z-
dc.date.available2021-09-09T14:36:07Z-
dc.date.created2021-06-17-
dc.date.issued2008-
dc.identifier.issn1226-4334-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/124967-
dc.description.abstractPurpose: Hyperventilation is no longer recommended as a prophylactic intervention during the first 24 hours after severe head injury. The vasoconstriction caused by reducing carbon dioxide (CO2) levels leads to cerebral ischemia, and multiple arterial punctures may be required in order to monitor hyperventilation in severe brain injury. However, end-tidal CO2 (Petco2) reflects arterial CO2 (Paco2) noninvasively. The aim of this study was to determine whether Petco2 can be successfully used instead of Paco2 to monitor hyperventilation in brain injury patients. Methods: From July 1, 2006 to June 30, 2007, 71 patients who visited the emergency department of a hospital after severe brain injury (trauma or acute cerebral disorder) were enrolled. Ten patients with chest trauma, 6 patients who received CPR in the emergency department (ED), and 1 patient who had COPD were excluded. Hemodynamic variables (Glasgow coma scale, mean arterial pressure, heart rate, respiration rate, body temperature, emergency operation, serum lactate concentration) under mechanical ventilation support were measured. The concordance between Petco2 and Paco2 was analyzed by employing a Bland- Altman plot. We defined the normal range for Paco2 and Petco2 [P(a-et)co2] is -5~5 mmHg. We compared the normal and high P(a-et)co2 groups to identify factors affecting the P(a-et)co2. Results: Excepting 17 patients under exclusion criteria, we analyzed 54 of the total of 71 patients. Thirteen patients (24.1%) were seen to be below 30 mmHg for Paco2. The Pearson correlation coefficient between Paco2 and Petco2 is 0.834 (p < 0.001), and the concordance between Paco2 and Petco2 was similarly high. The patients with high P(aet) co2 showed significantly lower mean arterial pressure and lower arterial pH than patients with normal P(a-et)co2. Conclusion: Petco2 shows high concordance with Paco2 in severe brain injury. However, patients with high P(a-et)co2 showed evidence of poor tissue perfusion. Therefore, the hemodynamic and tissue perfusion state should be considered when attempting to monitor hyperventilation in severe brain injury patients using Petco2.-
dc.languageKorean-
dc.language.isoko-
dc.publisher대한응급의학회-
dc.title중증 뇌손상 환자에게 비침습적 과호흡 감시로서 호기말 이산화탄소의 이용-
dc.title.alternativeThe Clinical Utility of End-tidal Carbon Dioxide as a Non-invasive Monitoring of Hyperventilation in Severe Brain Injury-
dc.typeArticle-
dc.contributor.affiliatedAuthor홍윤식-
dc.contributor.affiliatedAuthor최성혁-
dc.contributor.affiliatedAuthor문성우-
dc.identifier.bibliographicCitation대한응급의학회지, v.19, no.4, pp.392 - 397-
dc.relation.isPartOf대한응급의학회지-
dc.citation.title대한응급의학회지-
dc.citation.volume19-
dc.citation.number4-
dc.citation.startPage392-
dc.citation.endPage397-
dc.type.rimsART-
dc.identifier.kciidART001272724-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorEnd-tidal carbon dioxide-
dc.subject.keywordAuthorArterial carbon dioxide-
dc.subject.keywordAuthorBrain injuries-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Moon, Sung Woo photo

Moon, Sung Woo
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE