High performance gamma-ray imager using dual anti-mask method for the investigation of high-energy nuclear materials
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Taewoong | - |
dc.contributor.author | Lee, Wonho | - |
dc.date.accessioned | 2021-11-17T14:41:03Z | - |
dc.date.available | 2021-11-17T14:41:03Z | - |
dc.date.created | 2021-08-30 | - |
dc.date.issued | 2021-07 | - |
dc.identifier.issn | 1738-5733 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/127766 | - |
dc.description.abstract | As the gamma-ray energy increases, a reconstructed image becomes noisy and blurred due to the penetration of the gamma-ray through the coded mask. Therefore, the thickness of the coded mask was increased for high energy regions, resulting in severely decreased the performance of the detection efficiency due to self collimation by the mask. In order to overcome the limitation, a modified uniformly redundant array y ray imaging system using dual anti-mask method was developed, and its performance was compared and evaluated in high-energy radiation region. In the dual anti-mask method, the two shadow images, including the subtraction of background events, can simultaneously contribute to the reconstructed image. Moreover, the reconstructed images using each shadow image were integrated using a hybrid update maximum likelihood expectation maximization (h-MLEM). Using the quantitative evaluation method, the performance of the dual anti-mask method was compared with the previously developed collimation methods. As the shadow image which was subtracted the background events leads to a higher-quality reconstructed image, the reconstructed image of the dual anti-mask method showed high performance among the three collimation methods. Finally, the quantitative evaluation method proves that the performance of the dual anti-mask method was better than that of the previously reconstruction methods. (C) 2021 Korean Nuclear Society, Published by Elsevier Korea LLC. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | KOREAN NUCLEAR SOC | - |
dc.subject | CODED-APERTURE | - |
dc.subject | CAMERA | - |
dc.title | High performance gamma-ray imager using dual anti-mask method for the investigation of high-energy nuclear materials | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Wonho | - |
dc.identifier.doi | 10.1016/j.net.2021.01.027 | - |
dc.identifier.wosid | 000663396800003 | - |
dc.identifier.bibliographicCitation | NUCLEAR ENGINEERING AND TECHNOLOGY, v.53, no.7, pp.2371 - 2376 | - |
dc.relation.isPartOf | NUCLEAR ENGINEERING AND TECHNOLOGY | - |
dc.citation.title | NUCLEAR ENGINEERING AND TECHNOLOGY | - |
dc.citation.volume | 53 | - |
dc.citation.number | 7 | - |
dc.citation.startPage | 2371 | - |
dc.citation.endPage | 2376 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART002726226 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Nuclear Science & Technology | - |
dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
dc.subject.keywordPlus | CODED-APERTURE | - |
dc.subject.keywordPlus | CAMERA | - |
dc.subject.keywordAuthor | Dual anti-mask method | - |
dc.subject.keywordAuthor | Hybrid update maximum likelihood | - |
dc.subject.keywordAuthor | expectation maximization (h-MLEM) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.