Variation of heart and lung radiation doses according to setup uncertainty in left breast cancer

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Sunmin-
dc.contributor.authorRim, Chai Hong-
dc.contributor.authorYoon, Won Sup-
dc.date.accessioned2021-11-21T08:41:12Z-
dc.date.available2021-11-21T08:41:12Z-
dc.date.created2021-08-30-
dc.date.issued2021-04-20-
dc.identifier.issn1748-717X-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/128217-
dc.description.abstractPurposeBreast radiotherapy set-up is often uncertain. Actual dose distribution to normal tissues could be different from planned dose distribution. The objective of this study was to investigate such difference in dose distribution according to the extent of set-up error in breast radiotherapy. Materials and methodsA total of 50 Gy with fraction size of 2 Gy was given to 30 left breasts with different set-ups applying a deep inspiration breath holding (DIBH) or a free breathing (FB) technique. Under the assumption that errors might come from translational axes of deep or caudal directions, the isocenter was shifted from the original tangential alignment every 2.5 mm to simulate uncertainty of deep and caudal tangential set-up in DIBH and FB. Changes were evaluated for dosimetric parameters for the heart, the left ventricle (LV), the left anterior descending coronary artery (LAD), and the ipsilateral lung.ResultsOn the original plan, mean doses of heart and ipsilateral lung were 2.01.1 Gy and 3.7 +/- 1.4 Gy in DIBH and 8.4 +/- 1.3 Gy and 7.8 +/- 1.5 Gy in FB, respectively. The change of dose distribution for the heart in DIBH was milder than that in FB. The deeper the tangential set-up, the worse the heart, LV, LAD, and ipsilateral lung doses, showing as much as 49.4%, 56.4%, 90.3%, and 26.1% shifts, respectively, in 5 mm DIBH setup. The caudal set-up did not show significant dose difference. In multiple comparison of DIBH, differences of mean dose occurred in all 7.5 mm deep set-ups for the heart (p=0.025), the LV (p=0.049), and LAD (p=0.025) in DIBH.Conclusions To correct set-up error over indicated limitation for deep tangential set-up in DIBH at 5 mm action level, mean heart and ipsilateral lung doses are expected to increase approximately 50% and 25%, respectively.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherBMC-
dc.titleVariation of heart and lung radiation doses according to setup uncertainty in left breast cancer-
dc.typeArticle-
dc.contributor.affiliatedAuthorYoon, Won Sup-
dc.identifier.doi10.1186/s13014-021-01806-5-
dc.identifier.scopusid2-s2.0-85104544662-
dc.identifier.wosid000642238500002-
dc.identifier.bibliographicCitationRADIATION ONCOLOGY, v.16, no.1-
dc.relation.isPartOfRADIATION ONCOLOGY-
dc.citation.titleRADIATION ONCOLOGY-
dc.citation.volume16-
dc.citation.number1-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOncology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryOncology-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordAuthorBreast cancer-
dc.subject.keywordAuthorRadiotherapy-
dc.subject.keywordAuthorSet-up uncertainty-
dc.subject.keywordAuthorDeep inspiration breath holding-
dc.subject.keywordAuthorHeart-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE