Detection of Particulate Matters with a Field-Portable Microscope Using Side-Illuminated Total Internal Reflection
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yang, Haechang | - |
dc.contributor.author | Shin, Sanghoon | - |
dc.contributor.author | Seo, Dongmin | - |
dc.contributor.author | Park, Jaewon | - |
dc.contributor.author | Seo, Sungkyu | - |
dc.date.accessioned | 2021-11-22T08:41:01Z | - |
dc.date.available | 2021-11-22T08:41:01Z | - |
dc.date.created | 2021-08-30 | - |
dc.date.issued | 2021-04 | - |
dc.identifier.issn | 1424-8220 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/128337 | - |
dc.description.abstract | Field-portable observation and analysis of particulate matter (PM) is required to enhance healthy lives. Various types of the PM measurement methods are in use; however, each of these methods has significant limitations in that real time measurement is impossible, the detection system is bulky, or the measurement accuracy is insufficient. In this work, we introduce an optical method to perform a fast and accurate PM analysis with a higher-contrast microscopic image enabled by a side-illuminated total internal reflection (TIR) technique to be implemented in a compact device. The superiority of the proposed method was quantitatively demonstrated by comparing the signal-to-noise ratio of the proposed side-illuminated TIR method with a traditional halogen lamp-based transmission microscope. With the proposed device, signal-to-noise ratios (SNRs) for microbeads (5 similar to 20 mu m) and ultrafine dust particles (>5 mu m) increased 4.5 similar to 17 and 4 similar to 10 dB, respectively, compared to the conventional transmission microscope. As a proof of concept, the proposed method was also applied to a low-cost commercial smartphone toy microscope enabling field-portable detection of PMs. We believe that the proposed side-illuminated TIR PM detection device holds significant advantages over other commonly used systems due to its sufficient detection capability along with simple and compact configuration as well as low cost. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | MDPI | - |
dc.subject | AIR-POLLUTION | - |
dc.title | Detection of Particulate Matters with a Field-Portable Microscope Using Side-Illuminated Total Internal Reflection | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Seo, Sungkyu | - |
dc.identifier.doi | 10.3390/s21082745 | - |
dc.identifier.scopusid | 2-s2.0-85103971575 | - |
dc.identifier.wosid | 000644807700001 | - |
dc.identifier.bibliographicCitation | SENSORS, v.21, no.8 | - |
dc.relation.isPartOf | SENSORS | - |
dc.citation.title | SENSORS | - |
dc.citation.volume | 21 | - |
dc.citation.number | 8 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.subject.keywordPlus | AIR-POLLUTION | - |
dc.subject.keywordAuthor | particulate matter (PM) | - |
dc.subject.keywordAuthor | optical detection | - |
dc.subject.keywordAuthor | side illumination | - |
dc.subject.keywordAuthor | total internal reflection (TIR) | - |
dc.subject.keywordAuthor | field-portable microscope | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.