Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Evaluation of the adaptation of complete denture metal bases fabricated with dental CAD-CAM systems: An in vitro study

Full metadata record
DC Field Value Language
dc.contributor.authorYou, S.-G.-
dc.contributor.authorYou, S.-M.-
dc.contributor.authorKang, S.-Y.-
dc.contributor.authorBae, S.-Y.-
dc.contributor.authorKim, J.-H.-
dc.date.accessioned2021-12-03T14:42:17Z-
dc.date.available2021-12-03T14:42:17Z-
dc.date.created2021-08-31-
dc.date.issued2021-03-
dc.identifier.issn0022-3913-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/129143-
dc.description.abstractStatement of problem: Conventional fabrication of complete denture metal bases is being replaced by the computer-aided design and computer-aided manufacturing (CAD-CAM) systems. However, a comparative analysis of subtractive and additive CAD-CAM manufacturing techniques is lacking. Purpose: The purpose of this in vitro study was to compare the adaptation of complete denture metal bases fabricated by milling (subtractive manufacturing) and stereolithography apparatus (SLA) and digital light processing (DLP) (additive manufacturing). Material and methods: Thirty metal bases were manufactured by using the milling (MIL group), SLA (SLA group), and DLP (DLP group) techniques. The silicone replica technique was used to evaluate the adaptation of the complete denture metal bases, and 30 silicone blocks were fabricated. The silicone block was cut equally in the canine, first molar, and second molar areas. The gap between the model and the metal base was measured by using a digital microscope at the 3 locations, and the measured data were statistically analyzed by using a statistical software program (α=.05). Results: The gaps measured at the 3 areas showed significant differences in all 3 groups (P<.05). At the anterior, middle, and posterior areas, the SLA group showed the narrowest gap (302 ±31 μm, 241 ±39 μm, 201 ±43 μm, respectively). The SLA group also had the narrowest total gap of the metal bases (218 ±33 μm). Conclusions: The adaptation of the fabricated metal bases varied significantly across the techniques used but fell within a clinically allowable range. The SLA group was the most precise in the fabrication of complete denture metal bases. Further studies are required to analyze the effects of the layer thickness setting, wax elimination, and casting temperature on the adaptation of metal bases manufactured by using SLA. © 2020 Editorial Council for the Journal of Prosthetic Dentistry-
dc.languageEnglish-
dc.language.isoen-
dc.publisherMosby Inc.-
dc.subjectcomplete denture-
dc.subjectcomputer aided design-
dc.subjectdental marginal adaptation-
dc.subjectdenture base-
dc.subjectprosthesis design-
dc.subjectstereolithography-
dc.subjectComputer-Aided Design-
dc.subjectDental Marginal Adaptation-
dc.subjectDental Prosthesis Design-
dc.subjectDenture Bases-
dc.subjectDenture, Complete-
dc.subjectStereolithography-
dc.titleEvaluation of the adaptation of complete denture metal bases fabricated with dental CAD-CAM systems: An in vitro study-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, J.-H.-
dc.identifier.doi10.1016/j.prosdent.2020.01.039-
dc.identifier.scopusid2-s2.0-85083058711-
dc.identifier.wosid000626185900003-
dc.identifier.bibliographicCitationJournal of Prosthetic Dentistry, v.125, no.3, pp.479 - 485-
dc.relation.isPartOfJournal of Prosthetic Dentistry-
dc.citation.titleJournal of Prosthetic Dentistry-
dc.citation.volume125-
dc.citation.number3-
dc.citation.startPage479-
dc.citation.endPage485-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaDentistry, Oral Surgery & Medicine-
dc.relation.journalWebOfScienceCategoryDentistry, Oral Surgery & Medicine-
dc.subject.keywordPluscomplete denture-
dc.subject.keywordPluscomputer aided design-
dc.subject.keywordPlusdental marginal adaptation-
dc.subject.keywordPlusdenture base-
dc.subject.keywordPlusprosthesis design-
dc.subject.keywordPlusstereolithography-
dc.subject.keywordPlusComputer-Aided Design-
dc.subject.keywordPlusDental Marginal Adaptation-
dc.subject.keywordPlusDental Prosthesis Design-
dc.subject.keywordPlusDenture Bases-
dc.subject.keywordPlusDenture, Complete-
dc.subject.keywordPlusStereolithography-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ji Hwan photo

Kim, Ji Hwan
보건과학대학 (보건정책관리학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE