Impact analysis of recovery ramp rate after momentary cessation in inverter-based distributed generators on power system transient stability
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kang, Sungwoo | - |
dc.contributor.author | Shin, Heewon | - |
dc.contributor.author | Jang, Gilsoo | - |
dc.contributor.author | Lee, Byongjun | - |
dc.date.accessioned | 2021-12-04T23:00:26Z | - |
dc.date.available | 2021-12-04T23:00:26Z | - |
dc.date.created | 2021-08-30 | - |
dc.date.issued | 2021-01 | - |
dc.identifier.issn | 1751-8687 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/129468 | - |
dc.description.abstract | The global increase in the use of solar photovoltaics and wind turbines has led to a rapid increase in the penetration level of inverter-based distributed generators (IBDGs). Until recently, the operation modes of IBDGs under abnormal power system conditions were not a major concern owing to the small number of IBDGs used in power systems. However, several events have indicated that the momentary cessation (MC) mode of an IBDG can eventually deteriorate the stability of power systems. Among the various parameters that define the MC mode, the direct impact of the MC recovery ramp rate on the transient stability of the power system has been addressed by computing the stability margin based on a single machine equivalent method. Furthermore, this paper introduces the critical momentary cessation recovery ramp rate for a specific system, which can be used as an important index in the planning of an IBDG installation. Case studies on modified IEEE 39 bus system and Korean power system were conducted to validate the effectiveness of the proposed method. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | INST ENGINEERING TECHNOLOGY-IET | - |
dc.subject | ENERGY-STORAGE | - |
dc.title | Impact analysis of recovery ramp rate after momentary cessation in inverter-based distributed generators on power system transient stability | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Byongjun | - |
dc.identifier.doi | 10.1049/gtd2.12004 | - |
dc.identifier.scopusid | 2-s2.0-85108849091 | - |
dc.identifier.wosid | 000592452300001 | - |
dc.identifier.bibliographicCitation | IET GENERATION TRANSMISSION & DISTRIBUTION, v.15, no.1, pp.24 - 33 | - |
dc.relation.isPartOf | IET GENERATION TRANSMISSION & DISTRIBUTION | - |
dc.citation.title | IET GENERATION TRANSMISSION & DISTRIBUTION | - |
dc.citation.volume | 15 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 24 | - |
dc.citation.endPage | 33 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.subject.keywordPlus | ENERGY-STORAGE | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.