dc.description.abstract | This study presents the effects of blast-induced local damages on the flexural strength of blast-damaged and repaired specimens. In the experimental program, blast-damaged specimens were repaired with steel fiber reinforced cementitious composite (SFRCC) as well as carbon fiber-reinforced polymer (CFRP) sheets and tested for flexural strength measurements. The test parameters included shear reinforcement (amount and spacing), steel fiber content (0, 1.0 vol%), and retrofitting with CFRP sheets. The test results indicated that the use of higher amounts of stirrups demonstrated insignificant benefits in preventing local damages. However, it was shown that the use of small-diameter steel bars for stirrups with small spacing could decrease the local damages more effectively compared to the large-diameter steel reinforcement. For the residual strength of the damaged specimens, the specimens using more stirrups could resist over 60% of their original flexural strength. CFRP retrofitting showed insignificant enhancement in ductility of intact, damaged, and repaired specimens. However, it distributed the blast load and protected debris scattering. The addition of steel fibers results in increased ductility and enhanced blast resistance against local damages. All specimens, excluding control specimen, that repaired with SFRCC showed higher flexural strength to their original strength. Therefore, it can be concluded that replacing damaged concrete cover with SFRCC is adequate for repairing the blast-damaged RC members. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | HINDAWI LTD | - |
dc.subject | REINFORCED-CONCRETE | - |
dc.subject | RESISTANCE | - |
dc.subject | COMPOSITES | - |
dc.subject | CAPACITY | - |
dc.subject | SLABS | - |
dc.title | Flexural Assessment of Blast-Damaged RC Beam Retrofitted with CFRP Sheet and Steel Fiber | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Yoon, Young-Soo | - |
dc.identifier.doi | 10.1155/2018/2036436 | - |
dc.identifier.scopusid | 2-s2.0-85053780979 | - |
dc.identifier.wosid | 000436486800001 | - |
dc.identifier.bibliographicCitation | INTERNATIONAL JOURNAL OF POLYMER SCIENCE, v.2018 | - |
dc.relation.isPartOf | INTERNATIONAL JOURNAL OF POLYMER SCIENCE | - |
dc.citation.title | INTERNATIONAL JOURNAL OF POLYMER SCIENCE | - |
dc.citation.volume | 2018 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Polymer Science | - |
dc.relation.journalWebOfScienceCategory | Polymer Science | - |
dc.subject.keywordPlus | REINFORCED-CONCRETE | - |
dc.subject.keywordPlus | RESISTANCE | - |
dc.subject.keywordPlus | COMPOSITES | - |
dc.subject.keywordPlus | CAPACITY | - |
dc.subject.keywordPlus | SLABS | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.