Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Effect of Computer Navigation on Accuracy and Reliability of Limb Alignment Correction following Open-Wedge High Tibial Osteotomy: A Meta-Analysis

Full metadata record
DC Field Value Language
dc.contributor.authorHan, Seung-Beom-
dc.contributor.authorKim, Hyun Jung-
dc.contributor.authorLee, Dae-Hee-
dc.date.accessioned2021-12-21T15:41:08Z-
dc.date.available2021-12-21T15:41:08Z-
dc.date.created2021-08-30-
dc.date.issued2017-
dc.identifier.issn2314-6133-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/132424-
dc.description.abstractBackground. It is unclear whether computer navigation can improve the accuracy and reliability of targeted lower limb alignment correction following open-wedge high tibial osteotomy (HTO). This meta-analysis was designed to compare the accuracy and reliability of limb alignment correction between computer navigated and conventional open-wedge HTOs. Methods. Studies that compared postoperative coronal alignment, including mechanical axis (MA) and weight bearing line (WBL) ratio, outliers of alignment correction, and change in tibial posterior slope, following open-wedge HTO performed using computer navigated and conventional methods were included. Results. Ten studies were included in the meta-analysis. The MA (0.93 degrees; 95% confidence interval [CI]: 0.45-1.41 degrees; p < 0.001) and WBL ratio (1.5%; 95% CI: 0.03-2.98%; p = 0.048) were significantly greater for computer navigated HTO than for conventional HTO. Outliers of alignment correction after surgery were significantly lower in patients who underwent computer navigated HTO than in those who underwent conventional HTO (odds ratio: 0.25; 95% CI: 0.08-0.79; p = 0.02). Changes in posterior tibial slope frombefore to after surgery, however, were similar for the two approaches. Conclusion. Computer navigated HTO resulted in slightly more valgus postoperative alignment and effectively reduced outliers of alignment correction but had no effect on change in posterior tibial slope when compared with conventional HTO.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherHINDAWI LTD-
dc.subjectWEIGHT-BEARING-
dc.subjectCONVENTIONAL TECHNIQUE-
dc.subjectSYSTEM-
dc.subjectKNEE-
dc.subjectROTATION-
dc.subjectSLOPE-
dc.titleEffect of Computer Navigation on Accuracy and Reliability of Limb Alignment Correction following Open-Wedge High Tibial Osteotomy: A Meta-Analysis-
dc.typeArticle-
dc.contributor.affiliatedAuthorHan, Seung-Beom-
dc.identifier.doi10.1155/2017/3803457-
dc.identifier.scopusid2-s2.0-85042149483-
dc.identifier.wosid000412670500001-
dc.identifier.bibliographicCitationBIOMED RESEARCH INTERNATIONAL, v.2017-
dc.relation.isPartOfBIOMED RESEARCH INTERNATIONAL-
dc.citation.titleBIOMED RESEARCH INTERNATIONAL-
dc.citation.volume2017-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaBiotechnology & Applied Microbiology-
dc.relation.journalResearchAreaResearch & Experimental Medicine-
dc.relation.journalWebOfScienceCategoryBiotechnology & Applied Microbiology-
dc.relation.journalWebOfScienceCategoryMedicine, Research & Experimental-
dc.subject.keywordPlusWEIGHT-BEARING-
dc.subject.keywordPlusCONVENTIONAL TECHNIQUE-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordPlusKNEE-
dc.subject.keywordPlusROTATION-
dc.subject.keywordPlusSLOPE-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE