Double-bundle PCL reconstruction using tibial double cross-pin fixation
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lim, Hong Chul | - |
dc.contributor.author | Bae, Ji Hoon | - |
dc.contributor.author | Wang, Joon Ho | - |
dc.contributor.author | Yang, Jae Hyuk | - |
dc.contributor.author | Seok, Chang Woo | - |
dc.contributor.author | Kim, Hak Jun | - |
dc.contributor.author | Kim, Seung Joo | - |
dc.date.accessioned | 2022-01-05T13:40:27Z | - |
dc.date.available | 2022-01-05T13:40:27Z | - |
dc.date.created | 2021-08-30 | - |
dc.date.issued | 2010-01 | - |
dc.identifier.issn | 0942-2056 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/134488 | - |
dc.description.abstract | The purpose of this study was to assess the clinical results of arthroscopic double-bundle posterior cruciate ligament (PCL) reconstruction using double cross-pin fixation on the tibial side. Twenty-two patients who underwent PCL reconstruction using an Achilles tendon allograft with double cross-pins for tibial fixation were evaluated. There were 19 men and 3 women with mean age 36 years (range 18-59), and the average follow-up period was 33 months (range 24-60). Preoperative and postoperative knee functions were evaluated in all patients using Lysholm knee scores, the 2000 International Knee Documentation Committee (IKDC) grades, and Tegner activity scores. Median Lysholm knee scores were 64 (50-75) preoperatively and 88 (82-96), 89.9 +/- A 6.5 postoperatively (P < 0.001). Median side-to-side differences, determined using Telos stress radiographs, were 11 mm (8-14) preoperatively, and 3 mm (1-7) at final follow-up visits (P < 0.01). According to KT-2000 arthrometer measurements, mean side-to-side differences were 11 mm (8-13) preoperatively and 3 mm (1-6, P < 0.01) at final follow-up visits (P < 0.01). Preoperatively the 2000 IKDC evaluation system rated all patients as abnormal or severely abnormal (C or D), and at final follow-up visits, 20 patients (88%) were rated as normal or nearly normal (A or B) and 2 patients (12%) were rated as abnormal (C). Median preinjury and preoperative Tegner scores were 7 (range 5-9) and 3 (range 2-5), respectively, and the mean postoperative Tegner score was 6 (range 3-9). There were no intraoperative or postoperative complications. Our study shows that arthroscopic double-bundle PCL reconstruction using an Achilles allograft with double cross-pins for tibial fixation provides satisfactory clinical results given a mean follow-up of 33 months. We believe that this method provides a reliable alternative technique of PCL reconstruction. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | SPRINGER | - |
dc.subject | POSTERIOR CRUCIATE LIGAMENT | - |
dc.subject | INTERFERENCE SCREW FIXATION | - |
dc.subject | HAMSTRING TENDON AUTOGRAFT | - |
dc.subject | GRAFT FIXATION | - |
dc.subject | TRANSTIBIAL TECHNIQUES | - |
dc.subject | MINIMUM | - |
dc.subject | KNEE | - |
dc.subject | INLAY | - |
dc.subject | KINEMATICS | - |
dc.subject | STABILITY | - |
dc.title | Double-bundle PCL reconstruction using tibial double cross-pin fixation | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lim, Hong Chul | - |
dc.contributor.affiliatedAuthor | Bae, Ji Hoon | - |
dc.contributor.affiliatedAuthor | Kim, Hak Jun | - |
dc.identifier.doi | 10.1007/s00167-009-0812-2 | - |
dc.identifier.scopusid | 2-s2.0-73249125665 | - |
dc.identifier.wosid | 000273093100022 | - |
dc.identifier.bibliographicCitation | KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, v.18, no.1, pp.117 - 122 | - |
dc.relation.isPartOf | KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY | - |
dc.citation.title | KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY | - |
dc.citation.volume | 18 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 117 | - |
dc.citation.endPage | 122 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Orthopedics | - |
dc.relation.journalResearchArea | Sport Sciences | - |
dc.relation.journalResearchArea | Surgery | - |
dc.relation.journalWebOfScienceCategory | Orthopedics | - |
dc.relation.journalWebOfScienceCategory | Sport Sciences | - |
dc.relation.journalWebOfScienceCategory | Surgery | - |
dc.subject.keywordPlus | POSTERIOR CRUCIATE LIGAMENT | - |
dc.subject.keywordPlus | INTERFERENCE SCREW FIXATION | - |
dc.subject.keywordPlus | HAMSTRING TENDON AUTOGRAFT | - |
dc.subject.keywordPlus | GRAFT FIXATION | - |
dc.subject.keywordPlus | TRANSTIBIAL TECHNIQUES | - |
dc.subject.keywordPlus | MINIMUM | - |
dc.subject.keywordPlus | KNEE | - |
dc.subject.keywordPlus | INLAY | - |
dc.subject.keywordPlus | KINEMATICS | - |
dc.subject.keywordPlus | STABILITY | - |
dc.subject.keywordAuthor | Posterior cruciate ligament | - |
dc.subject.keywordAuthor | Double-bundle reconstruction | - |
dc.subject.keywordAuthor | Cross-pin fixation | - |
dc.subject.keywordAuthor | Achilles tendon allograft | - |
dc.subject.keywordAuthor | RigidFix | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.