Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Stretchable array of CdSe/ZnS quantum-dot light emitting diodes for visual display of bio-signals

Authors
Lee, YonghuiKim, Dong SikJin, Sang WooLee, HanchanJeong, Yu RaYou, IlhwanZi, GoangseupHa, Jeong Sook
Issue Date
1-1월-2022
Publisher
ELSEVIER SCIENCE SA
Keywords
Bio-signals; Body movement; Liquid metal; QD-LED; Skin temperature; Stretchable display
Citation
CHEMICAL ENGINEERING JOURNAL, v.427
Indexed
SCIE
SCOPUS
Journal Title
CHEMICAL ENGINEERING JOURNAL
Volume
427
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/135275
DOI
10.1016/j.cej.2021.130858
ISSN
1385-8947
Abstract
Display devices that can visually present various bio-signals are a core future technology required for skin attachable wearable electronics. Quantum dot light emitting diodes (QD-LEDs), which can be used as high performance display devices, exhibit many advantages such as a narrow bandwidth, high color purity, high environmental stability, easy and fast processing, and a high brightness at low voltage. In this study, we report on the fabrication of a stretchable QD-LED array for the visual display of body movement and skin temperature signals from skin-attached sensors. After forming an array of a rigid NOA63 islands, an array of CdSe/ZnS QDLEDs is fabricated on top of that island array and electrically connected using liquid metal Galinstan interconnections. Finally, the array of QD-LEDs on the NOA63 islands is transferred onto a stretchable elastomer substrate of Ecoflex/PDMS. Of particular importance, for stable performance of the QD-LEDs under deformation, in replacement of the conventionally used ITO, a flexible and highly transparent electrode of Au grid/Ethylene glycol doped PEDOT:PSS is used. Such a design architecture can minimize the strain applied to the QD-LEDs by concentrating the strain onto the soft elastomer film substrate and the Galinstan interconnections. As a result, the fabricated QD-LED array exhibits stable operation under both 50% uniaxial and 30% biaxial strains. After attachment of the stretchable QD-LED array onto skin, the extent of knee bending, and changes in skin temperature are displayed as changes in the pattern of the QD-LED array. This work demonstrates the potential application of our stretchable array of QD-LEDs for easy and daily monitoring of health conditions through a visual display.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Chemical and Biological Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Ha, Jeong Sook photo

Ha, Jeong Sook
공과대학 (화공생명공학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE