Performance improvement of heat pumps by optimizing refrigerant charge using novel variable liquid-line length system

Full metadata record
DC Field Value Language
dc.contributor.authorLee, DongChan-
dc.contributor.authorLee, Minwoo-
dc.contributor.authorCho, Wonhee-
dc.contributor.authorKim, Yongchan-
dc.date.accessioned2022-02-24T22:40:32Z-
dc.date.available2022-02-24T22:40:32Z-
dc.date.created2021-12-07-
dc.date.issued2021-09-
dc.identifier.issn1359-4311-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/136790-
dc.description.abstractHeat pumps are often operated with nonoptimal amounts of refrigerant charge under various operating conditions; this results in excessive energy consumption by the air-conditioning systems in buildings. This paper proposes a novel variable liquid-line length system (VLLS) to improve the performance of heat pumps by optimizing the amount of refrigerant charge under various operating conditions. The feasibility of the VLLS is experimentally verified by proving that changes in the condensing and evaporating pressures afford the same effects as those of varying the amount of refrigerant charge. The performance improvement in the heat pump using the VLLS was evaluated by varying the heat sink and source temperatures under a fixed electronic expansion valve (EEV) opening and fixed superheat. The results indicate that the VLLS with a fixed EEV opening enhances the maximum capacity and coefficient of performance (COP) of the heat pump by appropriately controlling superheat and subcooling under various operating conditions. Furthermore, the heat pump adopting the VLLS with a fixed superheat exhibits substantial improvements in the heating and cooling COPs by varying the optimal amount of refrigerant charge.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.subjectEXPANSION DEVICE-
dc.subjectAIR-CONDITIONER-
dc.subjectMASS CHARGE-
dc.subjectOPTIMIZATION-
dc.titlePerformance improvement of heat pumps by optimizing refrigerant charge using novel variable liquid-line length system-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Yongchan-
dc.identifier.doi10.1016/j.applthermaleng.2021.117287-
dc.identifier.scopusid2-s2.0-85108940445-
dc.identifier.wosid000686900800003-
dc.identifier.bibliographicCitationAPPLIED THERMAL ENGINEERING, v.196-
dc.relation.isPartOfAPPLIED THERMAL ENGINEERING-
dc.citation.titleAPPLIED THERMAL ENGINEERING-
dc.citation.volume196-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaThermodynamics-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaMechanics-
dc.relation.journalWebOfScienceCategoryThermodynamics-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.relation.journalWebOfScienceCategoryEngineering, Mechanical-
dc.relation.journalWebOfScienceCategoryMechanics-
dc.subject.keywordPlusAIR-CONDITIONER-
dc.subject.keywordPlusEXPANSION DEVICE-
dc.subject.keywordPlusMASS CHARGE-
dc.subject.keywordPlusOPTIMIZATION-
dc.subject.keywordAuthorHeat pump-
dc.subject.keywordAuthorOptimization-
dc.subject.keywordAuthorPerformance improvement-
dc.subject.keywordAuthorRefrigerant charge-
dc.subject.keywordAuthorVariable liquid-line length-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher KIM, Yong Chan photo

KIM, Yong Chan
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE