Energy Saving Quantitative Analysis of Passive, Active, and Renewable Technologies in Different Climate Zones
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Chul-Ho | - |
dc.contributor.author | Park, Min-Kyeong | - |
dc.contributor.author | Kang, Won-Hee | - |
dc.date.accessioned | 2022-02-25T18:40:56Z | - |
dc.date.available | 2022-02-25T18:40:56Z | - |
dc.date.created | 2022-02-11 | - |
dc.date.issued | 2021-08 | - |
dc.identifier.issn | 2076-3417 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/136891 | - |
dc.description.abstract | The purpose of this study was to provide a guideline for the selection of technologies suitable for ASHRAE international climate zones when designing high-performance buildings. In this study, high-performance technologies were grouped as passive, active, and renewable energy systems. Energy saving technologies comprising 15 cases were categorized into passive, active, and renewable energy systems. EnergyPlus v9.5.0 was used to analyze the contribution of each technology in reducing the primary energy consumption. The energy consumption of each system was analyzed in different climates (Incheon, New Delhi, Minneapolis, Berlin), and the detailed contributions to saving energy were evaluated. Even when the same technology is applied, the energy saving rate differs according to the climatic characteristics. Shading systems are passive systems that are more effective in hot regions. In addition, the variable air volume (VAV) system, combined VAV-energy recovery ventilation (ERV), and combined VAV-underfloor air distribution (UFAD) are active systems that can convert hot and humid outdoor temperatures to create comfortable indoor environments. In cold and cool regions, passive systems that prevent heat loss, such as high-R insulation walls and windows, are effective. Active systems that utilize outdoor air or ventilation include the combined VAV-economizer, the active chilled beam with dedicated outdoor air system (DOAS), and the combined VAV-ERV. For renewable energy systems, the ground source heat pump (GSHP) is more effective. Selecting energy saving technologies that are suitable for the surrounding environment, and selecting design strategies that are appropriate for a given climate, are very important for the design of high-performance buildings globally. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | MDPI | - |
dc.subject | PERFORMANCE | - |
dc.subject | BUILDINGS | - |
dc.subject | SYSTEMS | - |
dc.subject | COMFORT | - |
dc.subject | EFFICIENCY | - |
dc.subject | DESIGN | - |
dc.subject | MODEL | - |
dc.subject | HEAT | - |
dc.title | Energy Saving Quantitative Analysis of Passive, Active, and Renewable Technologies in Different Climate Zones | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Chul-Ho | - |
dc.identifier.doi | 10.3390/app11157115 | - |
dc.identifier.scopusid | 2-s2.0-85112651374 | - |
dc.identifier.wosid | 000681856800001 | - |
dc.identifier.bibliographicCitation | APPLIED SCIENCES-BASEL, v.11, no.15 | - |
dc.relation.isPartOf | APPLIED SCIENCES-BASEL | - |
dc.citation.title | APPLIED SCIENCES-BASEL | - |
dc.citation.volume | 11 | - |
dc.citation.number | 15 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Materials Science | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Engineering, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Materials Science, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.subject.keywordPlus | BUILDINGS | - |
dc.subject.keywordPlus | COMFORT | - |
dc.subject.keywordPlus | DESIGN | - |
dc.subject.keywordPlus | EFFICIENCY | - |
dc.subject.keywordPlus | HEAT | - |
dc.subject.keywordPlus | MODEL | - |
dc.subject.keywordPlus | PERFORMANCE | - |
dc.subject.keywordPlus | SYSTEMS | - |
dc.subject.keywordAuthor | ASHRAE international climate zones | - |
dc.subject.keywordAuthor | EnergyPlus | - |
dc.subject.keywordAuthor | active systems | - |
dc.subject.keywordAuthor | high-performance buildings | - |
dc.subject.keywordAuthor | passive systems | - |
dc.subject.keywordAuthor | renewable energy systems | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.