Effect of Exposure Angulation on the Occupational Radiation Exposure during Cardiac Angiography: Simulation Study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Roh, Younghoon | - |
dc.contributor.author | Kim, Jungsu | - |
dc.contributor.author | Park, Hyemin | - |
dc.contributor.author | Kim, Jungmin | - |
dc.contributor.author | Ryu, Dongryeol | - |
dc.contributor.author | Chun, Kwangjin | - |
dc.contributor.author | Seo, Jeonghun | - |
dc.contributor.author | Lee, Bongki | - |
dc.contributor.author | Cho, Byungryul | - |
dc.contributor.author | Yoon, Yongsu | - |
dc.date.accessioned | 2022-02-26T11:40:54Z | - |
dc.date.available | 2022-02-26T11:40:54Z | - |
dc.date.created | 2022-02-07 | - |
dc.date.issued | 2021-08 | - |
dc.identifier.issn | 1661-7827 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/137009 | - |
dc.description.abstract | Cardiac angiography to visualize the cardiac coronary artery for lesions causes a lot of radiation exposure dose to the interventional cardiologist. We evaluated the occupational radiation exposure to the interventional cardiologist based on changes to the angle of the X-ray tube used in cardiac angiography and calculated the conversion factor for effective dose in this study. To evaluate the occupational radiation exposure resulting from scattered radiation to interventional cardiologists, organ doses for eyeball, thyroid, and heart were calculated using Monte Carlo simulation with korean typical man(KTMAN) phantom at the left anterior oblique (LAO)30/cranial (CRAN)30, CRAN40, right anterior oblique (RAO)30/CRAN30, RAO30/caudal(CAUD)20, CAUD39, LAO40/CAUD35, and LAO40 positions in the femoral and the radial artery puncture. In this study, analysis of the different angles showed the highest radiation exposure on LAO30/CRAN30 and CRAN40 position, which were 150.65% and 135.3%, respectively, compared to AP angles. Therefore, to reduce occupational dose for interventional cardiologists, it is recommended that radiation protection, such as using radiation shield and personal protective equipment (PPE), be used at LAO30/CRAN30 and CRAN40 angulation, and the conversion factor for calculating the organ dose received by the interventional cardiologists based on patient dose can be applied for improved occupational dose management. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | MDPI | - |
dc.subject | CONVERSION FACTORS | - |
dc.subject | CARDIOLOGISTS | - |
dc.subject | BRAIN | - |
dc.title | Effect of Exposure Angulation on the Occupational Radiation Exposure during Cardiac Angiography: Simulation Study | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Jungmin | - |
dc.identifier.doi | 10.3390/ijerph18158097 | - |
dc.identifier.scopusid | 2-s2.0-85111387694 | - |
dc.identifier.wosid | 000681800800001 | - |
dc.identifier.bibliographicCitation | INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, v.18, no.15 | - |
dc.relation.isPartOf | INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH | - |
dc.citation.title | INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH | - |
dc.citation.volume | 18 | - |
dc.citation.number | 15 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | ssci | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Environmental Sciences & Ecology | - |
dc.relation.journalResearchArea | Public, Environmental & Occupational Health | - |
dc.relation.journalWebOfScienceCategory | Environmental Sciences | - |
dc.relation.journalWebOfScienceCategory | Public, Environmental & Occupational Health | - |
dc.subject.keywordPlus | BRAIN | - |
dc.subject.keywordPlus | CARDIOLOGISTS | - |
dc.subject.keywordPlus | CONVERSION FACTORS | - |
dc.subject.keywordAuthor | Monte Carlo simulation | - |
dc.subject.keywordAuthor | cardiac angiography | - |
dc.subject.keywordAuthor | occupational radiation exposure | - |
dc.subject.keywordAuthor | organ-dose | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.