Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Impact of chronic outward force on arterial responses of proximal and distal of long superficial femoral artery stent

Full metadata record
DC Field Value Language
dc.contributor.authorLi, Hu-
dc.contributor.authorRha, Seung-Woon-
dc.contributor.authorChoi, Byoung Geol-
dc.contributor.authorChoi, Se Yeon-
dc.contributor.authorMoon, Sang Ki-
dc.contributor.authorJang, Won Young-
dc.contributor.authorKim, Woohyeun-
dc.contributor.authorAhn, Ji Hun-
dc.contributor.authorPark, Sang-Ho-
dc.contributor.authorChoi, Woong Gil-
dc.contributor.authorYang, Rui Feng-
dc.contributor.authorBai, Wen Wei-
dc.contributor.authorChoi, Cheol Ung-
dc.contributor.authorRyu, Yang Gi-
dc.contributor.authorBaek, Man Jong-
dc.contributor.authorOh, Dong Joo-
dc.date.accessioned2022-02-28T18:42:07Z-
dc.date.available2022-02-28T18:42:07Z-
dc.date.created2022-02-09-
dc.date.issued2021-06-30-
dc.identifier.issn1471-2261-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/137284-
dc.description.abstractBackgroundSelf-expanding nitinol stent (SENS) implantation is commonly oversized in the superficial femoral artery (SFA), and leads to chronic outward force (COF) and in-stent restenosis (ISR). This study aimed to investigate the impact of COF of oversizing SENS on ISR of SFA. MethodsIn patients with implanted SENS in SFA, intimal hyperplasia especially between proximal segment and distal segment was evaluated by quantitative angiography, and the impact of COF on mid-term angiographic outcomes was investigated. In addition, porcine model with implanted SENS was used to evaluate the impact of COF on angiographic and histopathologic outcomes at 1 month. Excised stented arteries were evaluated by histopathologic analysis.ResultsWe analyzed 65 SENS in 61 patients with follow-up angiography at 6 months to 1 year. The baseline diameter was 6.80.71 mm and length were 97.0 +/- 33.8 mm for the SENS. The ratio of the diameter of the stent to the reference vessel was 1.3 +/- 0.24 at the proximal portion and 1.53 +/- 0.27 at the distal portion (P<0.001). In the long SFA stent, stent-to-vessel ratio was significantly higher in the distal stent than in the proximal stent (1.3<plus/minus>0.2 vs. 1.55 +/- 0.25, P=0.001). ISR incidence was higher at the distal stent (37.3% vs 52.6%, P=0.029). All 11 pigs survived for 4 weeks after SENS implantation. The vessel diameter was 4.04 +/- 0.40 mm (control group) vs 4.45 +/- 0.63 mm (oversized group), and the implanted stent diameter was 5.27 +/- 0.46 mm vs. 7.18 +/- 0.4 mm (P=0.001). The stent-to-vessel diameter ratio was 1.31 +/- 0.12 versus 1.63 +/- 0.20 (P<0.001). After 4 weeks, restenosis % was 29.5<plus/minus>12.9% versus 46.8 +/- 21.5% (P=0.016). The neointimal area was 5.37 +/- 1.15 mm(2) vs. 8.53 +/- 5.18 mm(2) (P=0.05). The restenosis % was 39.34 +/- 8.53% versus 63.97 +/- 17.1% (P=0.001).Conclusions COF is an important cause of restenosis in the distal portion of the SFA stent. Optimal sizing of the SFA stent is important to reduce the incidence of restenosis. Therefore, COF was an important factor of restenosis following distal SFA stenting.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherBMC-
dc.subjectSELF-EXPANDING STENTS-
dc.subjectNITINOL STENT-
dc.subjectBALLOON ANGIOPLASTY-
dc.subjectFEMOROPOPLITEAL ARTERY-
dc.subjectNEOINTIMAL HYPERPLASIA-
dc.subjectIMPLANTATION-
dc.subjectLESIONS-
dc.subjectRESTENOSIS-
dc.subjectPLACEMENT-
dc.subjectOUTCOMES-
dc.titleImpact of chronic outward force on arterial responses of proximal and distal of long superficial femoral artery stent-
dc.typeArticle-
dc.contributor.affiliatedAuthorRha, Seung-Woon-
dc.identifier.doi10.1186/s12872-021-02141-z-
dc.identifier.scopusid2-s2.0-85109012681-
dc.identifier.wosid000671261900006-
dc.identifier.bibliographicCitationBMC CARDIOVASCULAR DISORDERS, v.21, no.1-
dc.relation.isPartOfBMC CARDIOVASCULAR DISORDERS-
dc.citation.titleBMC CARDIOVASCULAR DISORDERS-
dc.citation.volume21-
dc.citation.number1-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaCardiovascular System & Cardiology-
dc.relation.journalWebOfScienceCategoryCardiac & Cardiovascular Systems-
dc.subject.keywordPlusBALLOON ANGIOPLASTY-
dc.subject.keywordPlusFEMOROPOPLITEAL ARTERY-
dc.subject.keywordPlusIMPLANTATION-
dc.subject.keywordPlusLESIONS-
dc.subject.keywordPlusNEOINTIMAL HYPERPLASIA-
dc.subject.keywordPlusNITINOL STENT-
dc.subject.keywordPlusOUTCOMES-
dc.subject.keywordPlusPLACEMENT-
dc.subject.keywordPlusRESTENOSIS-
dc.subject.keywordPlusSELF-EXPANDING STENTS-
dc.subject.keywordAuthorChronic outward force-
dc.subject.keywordAuthorHistomorphometry-
dc.subject.keywordAuthorSelf-expanding nitinol stents-
dc.subject.keywordAuthorStent oversizing-
dc.subject.keywordAuthorSuperficial femoral artery-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Rha, Seung Woon photo

Rha, Seung Woon
의과학과
Read more

Altmetrics

Total Views & Downloads

BROWSE