Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Nanoparticle-based multiplex biosensor utilising dual dielectrophoretic forces for clinical diagnosis of Alzheimer's disease

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Hye Jin-
dc.contributor.authorAhn, Heeju-
dc.contributor.authorKim, Hongrae-
dc.contributor.authorPark, Dongsung-
dc.contributor.authorSan Lee, Jin-
dc.contributor.authorLee, Byung Chul-
dc.contributor.authorKim, Jinsik-
dc.contributor.authorYoon, Dae Sung-
dc.contributor.authorHwang, Kyo Seon-
dc.date.accessioned2022-03-02T07:42:04Z-
dc.date.available2022-03-02T07:42:04Z-
dc.date.created2022-03-02-
dc.date.issued2022-03-15-
dc.identifier.issn0925-4005-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/137482-
dc.description.abstractThe significant correlation between amyloid-beta (A beta) and tau accumulated in the brain and the levels observed in plasma means that the quantification of plasma A beta and tau is gaining attention as an alternative to conventional Alzheimer's disease (AD) diagnostic methods, such as neuroimaging and psychological memory evaluation. However, there remain limitations, such as low accuracy and reproducibility of AD diagnosis using plasma A beta and tau quantification in clinical samples. Here, we propose an interdigitated microelectrode (IMEs)-based impedimetric biosensor that uses polystyrene beads (PS) and dielectrophoretic (DEP) force and demonstrate its clinical applicability in AD diagnosis. In the quantification of A beta and tau present in 1% standard plasma as well as in phosphate-buffered saline (PBS), the biosensor showed almost more than 2-fold higher sensitivity compared to the reference without PS and DEP force. Furthermore, by quantifying the levels of A beta and tau in the clinical plasma samples, we successfully distinguished between clinically diagnosed AD patients and normal controls with high accuracy (p < 0.0001). These results suggest that our biosensor has high applicability and excellent potential for the clinical diagnosis of AD.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE SA-
dc.subjectAMYLOID-BETA-
dc.subjectPLASMA-
dc.titleNanoparticle-based multiplex biosensor utilising dual dielectrophoretic forces for clinical diagnosis of Alzheimer's disease-
dc.typeArticle-
dc.contributor.affiliatedAuthorYoon, Dae Sung-
dc.identifier.doi10.1016/j.snb.2021.131288-
dc.identifier.scopusid2-s2.0-85121719189-
dc.identifier.wosid000744566600007-
dc.identifier.bibliographicCitationSENSORS AND ACTUATORS B-CHEMICAL, v.355-
dc.relation.isPartOfSENSORS AND ACTUATORS B-CHEMICAL-
dc.citation.titleSENSORS AND ACTUATORS B-CHEMICAL-
dc.citation.volume355-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaElectrochemistry-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryElectrochemistry-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.subject.keywordPlusAMYLOID-BETA-
dc.subject.keywordPlusPLASMA-
dc.subject.keywordAuthorAlzheimer&apos-
dc.subject.keywordAuthors disease-
dc.subject.keywordAuthorAmyloid-beta-
dc.subject.keywordAuthorTau-
dc.subject.keywordAuthorMultiplexing-
dc.subject.keywordAuthorPolystyrene bead-
dc.subject.keywordAuthorDielectrophoresis-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Bioengineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE