Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Diagnostic clues of IOP pulsation on applanation tonometry in carotid-cavernous fistula patients

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Hyunkyu-
dc.contributor.authorYoon, Sumin-
dc.contributor.authorBaek, Sehyun-
dc.date.accessioned2022-03-02T16:42:30Z-
dc.date.available2022-03-02T16:42:30Z-
dc.date.created2022-03-02-
dc.date.issued2022-01-24-
dc.identifier.issn1471-2415-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/137523-
dc.description.abstractBackground Carotid-cavernous fistula (CCF) is an abnormal communication between the cavernous sinus and the carotid arterial system and exhibits typical symptoms of red eye, diplopia, blurred vision, headache, and murmur. However, the symptoms for CCF may vary and can lead to misdiagnosis. IOP pulsations provide a hint leading to suspicion of CCF. We report three cases related to CCF differential diagnosis: two cases of CCF patients and one case of conjunctivitis with corkscrew conjunctival vessels. Case presentation The case 1 patient, with a typical unilateral CCF, exhibited significant IOP pulsation in Goldmann tonometry measurements in the affected eye. The case 2 patient did not show typical symptoms of CCF except asymmetric upper eyelid swelling (right > left). In clinical evaluation, IOP elevation in the right eye and IOP pulsation in both eyes were noted. Based on radiology, the patient was diagnosed with bilateral CCF. The case 3 patient was referred to our institution for differential diagnosis of CCF. The patient had corkscrew conjunctival vessels in both eyes, which had appeared after he had been revived through CPR (cardiopulmonary resuscitation) 25 years prior. IOP pulsation was not observed in Goldmann tonometry. Radiology test result for arterio-venous fistula was negative in the case 3 patient. Conclusion For diagnosis of CCF, IOP pulsation by Goldmann applanation tonometry exhibits a good correlation with the disease in our cases and provides useful diagnostic clues.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherBMC-
dc.titleDiagnostic clues of IOP pulsation on applanation tonometry in carotid-cavernous fistula patients-
dc.typeArticle-
dc.contributor.affiliatedAuthorBaek, Sehyun-
dc.identifier.doi10.1186/s12886-022-02254-9-
dc.identifier.scopusid2-s2.0-85123470084-
dc.identifier.wosid000746615200004-
dc.identifier.bibliographicCitationBMC OPHTHALMOLOGY, v.22, no.1-
dc.relation.isPartOfBMC OPHTHALMOLOGY-
dc.citation.titleBMC OPHTHALMOLOGY-
dc.citation.volume22-
dc.citation.number1-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOphthalmology-
dc.relation.journalWebOfScienceCategoryOphthalmology-
dc.subject.keywordAuthorApplanation tonometry-
dc.subject.keywordAuthorCarotid-cavernous fistula-
dc.subject.keywordAuthorGoldmann tonometry-
dc.subject.keywordAuthorIOP pulsation-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Baek, Se Hyun photo

Baek, Se Hyun
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE