Evaluating the Accuracy (trueness and Precision) of Interim Crowns Manufactured Using Digital Light Processing According to Post-curing Time: an in Vitro Study

Full metadata record
DC Field Value Language
dc.contributor.authorLee, B.-I.-
dc.contributor.authorYou, S.-G.-
dc.contributor.authorYou, S.-M.-
dc.contributor.authorKim, D.-Y.-
dc.contributor.authorKim, J.-H.-
dc.date.accessioned2022-03-05T11:40:51Z-
dc.date.available2022-03-05T11:40:51Z-
dc.date.created2022-03-02-
dc.date.issued2021-04-
dc.identifier.issn2005-7806-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/137859-
dc.description.abstractPurpose. This study aimed to compare the accuracy (trueness and precision) of interim crowns fabricated using DLP (digital light processing) according to postcuring time. Materials and Methods. A virtual stone study die of the upper right first molar was created using a dental laboratory scanner. After designing interim crowns on the virtual study die and saving them as Standard Triangulated Language files, 30 interim crowns were fabricated using a DLP-type 3D printer. Additively manufactured interim crowns were post-cured using three different time conditions-10-minute post-curing interim crown (10-MPCI), 20-minute postcuring interim crown (20-MPCI), and 30-minute post-curing interim crown (30MPCI) (n = 10 per group). The scan data of the external and intaglio surfaces were overlapped with reference crown data, and trueness was measured using the best-fit alignment method. In the external and intaglio surface groups (n = 45 per group), precision was measured using a combination formula exclusive to scan data (10C2). Significant differences in accuracy (trueness and precision) data were analyzed using the Kruskal-Wallis H test, and post hoc analysis was performed using the Mann-Whitney U test with Bonferroni correction (α=.05). Results. In the 10-MPCI, 20-MPCI, and 30-MPCI groups, there was a statistically significant difference in the accuracy of the external and intaglio surfaces ( P <.05). On the external and intaglio surfaces, the root mean square (RMS) values of trueness and precision were the lowest in the 10-MPCI group. Conclusion. Interim crowns with 10-minute post-curing showed high accuracy. [J Adv Prosthodont 2021;13:89-99] © 2021 The Korean Academy of Prosthodontics-
dc.languageEnglish-
dc.language.isoen-
dc.publisherKorean Academy of Prosthodontic-
dc.titleEvaluating the Accuracy (trueness and Precision) of Interim Crowns Manufactured Using Digital Light Processing According to Post-curing Time: an in Vitro Study-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, J.-H.-
dc.identifier.doi10.4047/jap.2021.13.2.89-
dc.identifier.scopusid2-s2.0-85106573722-
dc.identifier.wosid000752474900001-
dc.identifier.bibliographicCitationJournal of Advanced Prosthodontics, v.13, no.2, pp.89 - 99-
dc.relation.isPartOfJournal of Advanced Prosthodontics-
dc.citation.titleJournal of Advanced Prosthodontics-
dc.citation.volume13-
dc.citation.number2-
dc.citation.startPage89-
dc.citation.endPage99-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART002708224-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaDentistry, Oral Surgery & Medicine-
dc.relation.journalWebOfScienceCategoryDentistry, Oral Surgery & Medicine-
dc.subject.keywordPlusDIMENSIONAL ACCURACY-
dc.subject.keywordPlusPROVISIONAL CROWNS-
dc.subject.keywordPlusLAYER THICKNESS-
dc.subject.keywordPlusORIENTATION-
dc.subject.keywordPlusFABRICATION-
dc.subject.keywordPlusPOLYMERS-
dc.subject.keywordPlusDENTURE-
dc.subject.keywordPlusTRIAL-
dc.subject.keywordPlusFIT-
dc.subject.keywordAuthorDigital light processing-
dc.subject.keywordAuthorInterim crown-
dc.subject.keywordAuthorPost-curing time-
dc.subject.keywordAuthorPrecision-
dc.subject.keywordAuthorTrueness-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > Division of Health Policy and Management > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Ji Hwan photo

Kim, Ji Hwan
보건과학대학 (보건정책관리학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE