Fault analysis in the grid with inverter-based distributed generation considering the interconnection transformer topology
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yoon, M. | - |
dc.contributor.author | Lee, M. | - |
dc.contributor.author | Cho, N. | - |
dc.contributor.author | Choi, S. | - |
dc.date.accessioned | 2022-03-10T02:42:27Z | - |
dc.date.available | 2022-03-10T02:42:27Z | - |
dc.date.created | 2022-02-09 | - |
dc.date.issued | 2021 | - |
dc.identifier.issn | 1975-8359 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/138418 | - |
dc.description.abstract | For conducting the fault analysis in a system with distributed generation, the sequence equivalent circuit is used. Due to the characteristics of distributed generation that reverse currents occur, the size of the fault current can be determined by the path where fault current can flow into the fault point in the negative sequence and zero sequence. In this paper, we calculate and compare the fault currents in the system with inverter-based distributed generation considering the topology of transformer winding. From the results, we can analyze the effect of the interconnection transformer in the fault analysis. Copyright © The Korean Institute of Electrical Engineers. | - |
dc.language | Korean | - |
dc.language.iso | ko | - |
dc.publisher | Korean Institute of Electrical Engineers | - |
dc.title | Fault analysis in the grid with inverter-based distributed generation considering the interconnection transformer topology | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Choi, S. | - |
dc.identifier.doi | 10.5370/KIEE.2021.70.9.1274 | - |
dc.identifier.scopusid | 2-s2.0-85115099710 | - |
dc.identifier.bibliographicCitation | Transactions of the Korean Institute of Electrical Engineers, v.70, no.9, pp.1274 - 1281 | - |
dc.relation.isPartOf | Transactions of the Korean Institute of Electrical Engineers | - |
dc.citation.title | Transactions of the Korean Institute of Electrical Engineers | - |
dc.citation.volume | 70 | - |
dc.citation.number | 9 | - |
dc.citation.startPage | 1274 | - |
dc.citation.endPage | 1281 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART002751475 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Distributed generation | - |
dc.subject.keywordAuthor | Fault analysis | - |
dc.subject.keywordAuthor | Fault current | - |
dc.subject.keywordAuthor | Interconnection transformer | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.