Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Algorithmic intraocular lens power calculation formula selection by keratometry, anterior chamber depth and axial length

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Jung Wan-
dc.contributor.authorEom, Youngsub-
dc.contributor.authorYoon, Eun Gyu-
dc.contributor.authorChoi, Young-
dc.contributor.authorSong, Jong Suk-
dc.contributor.authorJeong, Ji Won-
dc.contributor.authorPark, Seh Kwang-
dc.contributor.authorKim, Hyo Myung-
dc.date.accessioned2022-03-11T05:41:14Z-
dc.date.available2022-03-11T05:41:14Z-
dc.date.created2022-02-07-
dc.date.issued2022-05-
dc.identifier.issn1755-375X-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/138554-
dc.description.abstractPurpose To compare the prediction accuracy of algorithmic intraocular lens (IOL) power calculation formula selection method using conventional formulas (Haigis, Hoffer Q, Holladay 1, SRK/T and/or Barrett Universal II) based on keratometry (K), anterior chamber depth (ACD) and axial length (AL). Methods A total of 1653 patients (1653 eyes) implanted with Tecnis ZCB00 IOL during cataract surgery were enrolled in this study. Intraocular lens (IOL) power calculation formulas with a small absolute value in the sum of the area under the curve measured by K, ACD and AL subgroup were selected to calculate IOL power in the relevant biometry subgroup. The median absolute error (MedAE) calculated by the Haigis, Hoffer Q, Holladay 1, SRK/T and Barrett Universal II formulas individually was compared to that calculated by the algorithmic selection method using four formulas, Haigis, Hoffer Q, Holladay 1 and SRK/T, or five formulas when Barrett is included. Results The MedAE was 0.27 D in the Haigis, 0.30 D in the Hoffer Q, 0.27 D in the Holladay 1, 0.29 D in the SRK/T and 0.26 D in the Barrett Universal II formulas. The MedAEs determined by the algorithmic selection method using four (019 D) and five (0.21 D) formulas were significantly lower than those by the conventional IOL power calculation formulas. Conclusions The IOL power calculation formula selection method by biometry subgroup combined with biometric parameters K, ACD and AL may offer a more superior postoperative refractive error prediction in cataract surgery.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherWILEY-
dc.subjectHOFFER-Q-
dc.subjectACCURACY-
dc.subjectSURFACE-
dc.titleAlgorithmic intraocular lens power calculation formula selection by keratometry, anterior chamber depth and axial length-
dc.typeArticle-
dc.contributor.affiliatedAuthorEom, Youngsub-
dc.identifier.doi10.1111/aos.14956-
dc.identifier.scopusid2-s2.0-85112080874-
dc.identifier.wosid000683789400001-
dc.identifier.bibliographicCitationACTA OPHTHALMOLOGICA, v.100, no.3, pp.e701 - e709-
dc.relation.isPartOfACTA OPHTHALMOLOGICA-
dc.citation.titleACTA OPHTHALMOLOGICA-
dc.citation.volume100-
dc.citation.number3-
dc.citation.startPagee701-
dc.citation.endPagee709-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOphthalmology-
dc.relation.journalWebOfScienceCategoryOphthalmology-
dc.subject.keywordPlusHOFFER-Q-
dc.subject.keywordPlusACCURACY-
dc.subject.keywordPlusSURFACE-
dc.subject.keywordAuthoranterior chamber depth-
dc.subject.keywordAuthoraxial length-
dc.subject.keywordAuthorintraocular lens-
dc.subject.keywordAuthorkeratometry-
dc.subject.keywordAuthorpower-