Drawbacks of neural monitoring troubleshooting algorithms in transoral endoscopic thyroidectomy

Full metadata record
DC Field Value Language
dc.contributor.authorZhang, Daqi-
dc.contributor.authorWu, Che-Wei-
dc.contributor.authorWang, Tie-
dc.contributor.authorZhao, Yishen-
dc.contributor.authorKim, Hoon Yub-
dc.contributor.authorPino, Antonella-
dc.contributor.authorDionigi, Gianlorenzo-
dc.contributor.authorSun, Hui-
dc.date.accessioned2022-03-15T03:41:45Z-
dc.date.available2022-03-15T03:41:45Z-
dc.date.created2022-03-14-
dc.date.issued2021-11-
dc.identifier.issn1435-2443-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/139022-
dc.description.abstractIntroduction The application of intraoperative neural monitoring (IONM) trouble-shooting algorithms procedures in transoral endoscopic thyroidectomy vestibular approach (TOETVA) was investigated. Methods Loss of signal (LOS) is defined as a loss of the primary electromyographic (EMG) normal biphasic waveform with reduced amplitude response to less than 100 mu V with a stimulation level intensity of 1-2mA. A systematic review of the IONM system at LOS was covered methodically: (i) correct endotracheal tube verification, (ii) stimulation of the recurrent laryngeal nerve (RLN) at entry point, (iii) ipsilateral or contralateral vagal nerve (VN) stimulation, and (iv) laryngeal twitch (LT). Results The function of 223 nerves at risk (NAR) was recorded with IONM. Twenty-seven (12%) NAR experienced a suspected LOS. LT could not be appreciated. In 15/27 (55%) cases, the application of the IONM trouble-shooting algorithm revealed upward displacement of the EMG tube (all orotracheal intubations). In 9 (4%) NAR, VN stimulation was not accomplished. In detail, there were n.5 left and n. 4 right VNs. Two VNs were ipsilateral, and 7 VNs contralateral. For EMG tube displacement, because the oral/nasal area is included in the aseptic field, it is less possible to re-check by the laryngoscope or fiberscope. Conclusions A limit for applying the IONM trouble-shooting algorithm to TOETVA is determined by (a) inability to appreciate the LT, (b) difficulty in stimulating the ipsilateral and contralateral VN, and (c) remodeling EMG endotracheal tube position. A modified IONM trouble-shooting algorithm for TOETVA is proposed.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherSPRINGER-
dc.subjectRECURRENT LARYNGEAL NERVE-
dc.subjectVESTIBULAR APPROACH-
dc.subjectENDOTRACHEAL-TUBE-
dc.subjectSURGERY-
dc.titleDrawbacks of neural monitoring troubleshooting algorithms in transoral endoscopic thyroidectomy-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Hoon Yub-
dc.identifier.doi10.1007/s00423-021-02217-6-
dc.identifier.scopusid2-s2.0-85110055080-
dc.identifier.wosid000673908000001-
dc.identifier.bibliographicCitationLANGENBECKS ARCHIVES OF SURGERY, v.406, no.7, pp.2433 - 2440-
dc.relation.isPartOfLANGENBECKS ARCHIVES OF SURGERY-
dc.citation.titleLANGENBECKS ARCHIVES OF SURGERY-
dc.citation.volume406-
dc.citation.number7-
dc.citation.startPage2433-
dc.citation.endPage2440-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaSurgery-
dc.relation.journalWebOfScienceCategorySurgery-
dc.subject.keywordPlusENDOTRACHEAL-TUBE-
dc.subject.keywordPlusRECURRENT LARYNGEAL NERVE-
dc.subject.keywordPlusSURGERY-
dc.subject.keywordPlusVESTIBULAR APPROACH-
dc.subject.keywordAuthorMorbidity-
dc.subject.keywordAuthorNeuromonitoring-
dc.subject.keywordAuthorRecurrent laryngeal nerve-
dc.subject.keywordAuthorTOETVA-
dc.subject.keywordAuthorTransoral endoscopic thyroidectomy vestibular approach-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Hoon Yub photo

Kim, Hoon Yub
College of Medicine (Department of Medical Science)
Read more

Altmetrics

Total Views & Downloads

BROWSE