Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Safe Approach for Flexor Digitorum Profundus I and II Using the Palmaris Longus Tendon

Full metadata record
DC Field Value Language
dc.contributor.authorRyou, Chae Hyeon-
dc.contributor.authorShin, Se Young-
dc.contributor.authorKim, Nackhwan-
dc.contributor.authorKim, Ki Hoon-
dc.contributor.authorKim, Dong Hwee-
dc.contributor.authorLee, Hang Jae-
dc.date.accessioned2022-04-01T12:41:05Z-
dc.date.available2022-04-01T12:41:05Z-
dc.date.created2022-04-01-
dc.date.issued2022-03-
dc.identifier.issn0003-9993-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/139363-
dc.description.abstractObjective: To investigate a safe and accurate approach to achieve needle insertion for electromyography (EMG) of the flexor digitorum profundus (FDP) I and II muscles by identifying the anatomic relationship between the palmaris longus (PL) tendon, FDP muscle, and neurovascular bundle using ultrasonography. Design: Descriptive study Setting: Department of physical medicine and rehabilitation. Participants: Healthy individuals (age, 20-70y) without any diseases (N=29; 15 men, 14 women; 58 forearms). Interventions: Ultrasonography. Main Outcome Measures: The FDP I and II muscles were transversely scanned on the volar aspect of the forearm at the junction of the middle and distal third between the medial epicondyle and ulnar styloid process. The distances and angles from the medial border of the PL tendon to FDP I, FDP II, and median nerve were measured. Results: The probability of damage to the neurovascular structures and the accuracy of entering the FDP I and II muscles were calculated for 3 imaginary needle insertion angles (61.7 degrees, 100.6 degrees, and 90 degrees). When the needle was inserted at an angle of 61.7 degrees, it reached FDP I with an accuracy of 91.4%. Upon needle insertions at 90 degrees and 100.6 degrees, the needle reached FDP II with accuracies of 90% and 89.6%, respectively. In all 3 cases (61.7 degrees, 90 degrees, and 100.6 degrees), there was no chance of penetrating the blood vessels or nerves. Conclusion: EMG of FDP I and II can be performed precisely and safely with the anterior approach at the distal one-third between the medial epicondyle and ulnar styloid process using the PL tendon. (C) 2021 The American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherW B SAUNDERS CO-ELSEVIER INC-
dc.subjectMUSCLE-
dc.subjectINNERVATION-
dc.titleSafe Approach for Flexor Digitorum Profundus I and II Using the Palmaris Longus Tendon-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Dong Hwee-
dc.identifier.doi10.1016/j.apmr.2021.08.011-
dc.identifier.scopusid2-s2.0-85117898900-
dc.identifier.wosid000765768600014-
dc.identifier.bibliographicCitationARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, v.103, no.3, pp.488 - 493-
dc.relation.isPartOfARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION-
dc.citation.titleARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION-
dc.citation.volume103-
dc.citation.number3-
dc.citation.startPage488-
dc.citation.endPage493-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaRehabilitation-
dc.relation.journalResearchAreaSport Sciences-
dc.relation.journalWebOfScienceCategoryRehabilitation-
dc.relation.journalWebOfScienceCategorySport Sciences-
dc.subject.keywordPlusMUSCLE-
dc.subject.keywordPlusINNERVATION-
dc.subject.keywordAuthorElectromyography-
dc.subject.keywordAuthorRehabilitation-
dc.subject.keywordAuthorUltrasonography-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE