Evaluation of Building Energy Saving Through the Development of Venetian Blinds' Optimal Control Algorithm According to the Orientation and Window-to-Wall Ratio

Full metadata record
DC Field Value Language
dc.contributor.author이광호-
dc.date.accessioned2022-04-09T13:40:33Z-
dc.date.available2022-04-09T13:40:33Z-
dc.date.created2022-04-08-
dc.date.issued2018-02-
dc.identifier.issn0195-928X-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/139783-
dc.description.abstractAs various studies focusing on building energy saving have been continuously conducted, studies utilizing renewable energy sources, instead of fossil fuel, are needed. In particular, studies regarding solar energy are being carried out in the field of building science; in order to utilize such solar energy effectively, solar radiation being brought into the indoors should be acquired and blocked properly. Blinds are a typical solar radiation control device that is capable of controlling indoor thermal and light environments. However, slat-type blinds are manually controlled, giving a negative effect on building energy saving. In this regard, studies regarding the automatic control of slat-type blinds have been carried out for the last couple of decades. Therefore, this study aims to provide preliminary data for optimal control research through the controlling of slat angle in slat-type blinds by comprehensively considering various input variables. The window area ratio and orientation were selected as input variables. It was found that an optimal control algorithm was different among each window-to-wall ratio and window orientation. In addition, through comparing and analyzing the building energy saving performance for each condition by applying the developed algorithms to simula-
dc.languageEnglish-
dc.language.isoen-
dc.publisherSPRINGER/PLENUM PUBLISHERS-
dc.titleEvaluation of Building Energy Saving Through the Development of Venetian Blinds' Optimal Control Algorithm According to the Orientation and Window-to-Wall Ratio-
dc.typeArticle-
dc.contributor.affiliatedAuthor이광호-
dc.identifier.doi10.1007/s10765-017-2350-3-
dc.identifier.bibliographicCitationINTERNATIONAL JOURNAL OF THERMOPHYSICS, v.39, no.2-
dc.relation.isPartOfINTERNATIONAL JOURNAL OF THERMOPHYSICS-
dc.citation.titleINTERNATIONAL JOURNAL OF THERMOPHYSICS-
dc.citation.volume39-
dc.citation.number2-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.subject.keywordAuthorBuilding energy-
dc.subject.keywordAuthorEnergyPlus-
dc.subject.keywordAuthorOrientation-
dc.subject.keywordAuthorSlat angle-
dc.subject.keywordAuthorVenetian blind-
dc.subject.keywordAuthorWindow-to-wall ratio-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Architecture > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE