Evaluation of Building Energy Saving Through the Development of Venetian Blinds' Optimal Control Algorithm According to the Orientation and Window-to-Wall Ratio
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이광호 | - |
dc.date.accessioned | 2022-04-09T13:40:33Z | - |
dc.date.available | 2022-04-09T13:40:33Z | - |
dc.date.created | 2022-04-08 | - |
dc.date.issued | 2018-02 | - |
dc.identifier.issn | 0195-928X | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/139783 | - |
dc.description.abstract | As various studies focusing on building energy saving have been continuously conducted, studies utilizing renewable energy sources, instead of fossil fuel, are needed. In particular, studies regarding solar energy are being carried out in the field of building science; in order to utilize such solar energy effectively, solar radiation being brought into the indoors should be acquired and blocked properly. Blinds are a typical solar radiation control device that is capable of controlling indoor thermal and light environments. However, slat-type blinds are manually controlled, giving a negative effect on building energy saving. In this regard, studies regarding the automatic control of slat-type blinds have been carried out for the last couple of decades. Therefore, this study aims to provide preliminary data for optimal control research through the controlling of slat angle in slat-type blinds by comprehensively considering various input variables. The window area ratio and orientation were selected as input variables. It was found that an optimal control algorithm was different among each window-to-wall ratio and window orientation. In addition, through comparing and analyzing the building energy saving performance for each condition by applying the developed algorithms to simula | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | SPRINGER/PLENUM PUBLISHERS | - |
dc.title | Evaluation of Building Energy Saving Through the Development of Venetian Blinds' Optimal Control Algorithm According to the Orientation and Window-to-Wall Ratio | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 이광호 | - |
dc.identifier.doi | 10.1007/s10765-017-2350-3 | - |
dc.identifier.bibliographicCitation | INTERNATIONAL JOURNAL OF THERMOPHYSICS, v.39, no.2 | - |
dc.relation.isPartOf | INTERNATIONAL JOURNAL OF THERMOPHYSICS | - |
dc.citation.title | INTERNATIONAL JOURNAL OF THERMOPHYSICS | - |
dc.citation.volume | 39 | - |
dc.citation.number | 2 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.subject.keywordAuthor | Building energy | - |
dc.subject.keywordAuthor | EnergyPlus | - |
dc.subject.keywordAuthor | Orientation | - |
dc.subject.keywordAuthor | Slat angle | - |
dc.subject.keywordAuthor | Venetian blind | - |
dc.subject.keywordAuthor | Window-to-wall ratio | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.