Inverter-Embedded Partial Discharge Testing for Reliability Enhancement of Stator Winding Insulation in Low Voltage Machines
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Hyeonjun | - |
dc.contributor.author | Kim, Hanju | - |
dc.contributor.author | Jeong, Jigyun | - |
dc.contributor.author | Lee, Kibok | - |
dc.contributor.author | Lee, Sang Bin | - |
dc.contributor.author | Stone, Greg | - |
dc.date.accessioned | 2022-05-17T10:01:06Z | - |
dc.date.available | 2022-05-17T10:01:06Z | - |
dc.date.created | 2022-05-17 | - |
dc.date.issued | 2022-03 | - |
dc.identifier.issn | 0093-9994 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/141113 | - |
dc.description.abstract | Partial discharge (PD) due to high dv/dt pulsewidth modulation has been identified as one of the leading causes of insulation failure in low voltage (LV) variable frequency drive (VFD) fed motors with random wound stator windings. With the recent increase in electrical stress with faster risetime wide bandgap power semiconductor devices and higher dc link voltage for higher efficiency and power density of the system, PD-induced insulation failures are expected to increase. Since LV motor insulation is not resistant to PD, an increasing number of VFD motors are being qualified for PD-free operation. However, the PD inception voltage of qualified motors decreases with insulation aging making LV motors susceptible to failure. In this article, an offline standstill test method is proposed for automated inverter-embedded PD testing under impulse excitation. The main concept is to perform the impulse PD test using the VFD at increased voltage levels for providing advanced warning of PD activity for preventing forced outage of VFD motors. Options for application of increased impulse test voltage and automated detection of PD for implementing the proposed concept are presented. Testing on an 800 V VFD driven motor shows that the proposed method can provide automated impulse PD testing whenever the motor is at standstill to warn the end user of impending PD activity that can lead to failure. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
dc.subject | OFF-LINE | - |
dc.subject | MOTORS | - |
dc.subject | PD | - |
dc.subject | QUALITY | - |
dc.title | Inverter-Embedded Partial Discharge Testing for Reliability Enhancement of Stator Winding Insulation in Low Voltage Machines | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Sang Bin | - |
dc.identifier.doi | 10.1109/TIA.2022.3142712 | - |
dc.identifier.scopusid | 2-s2.0-85123279441 | - |
dc.identifier.wosid | 000771930400073 | - |
dc.identifier.bibliographicCitation | IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, v.58, no.2, pp.2088 - 2096 | - |
dc.relation.isPartOf | IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS | - |
dc.citation.title | IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS | - |
dc.citation.volume | 58 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 2088 | - |
dc.citation.endPage | 2096 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Engineering, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.subject.keywordPlus | OFF-LINE | - |
dc.subject.keywordPlus | MOTORS | - |
dc.subject.keywordPlus | PD | - |
dc.subject.keywordPlus | QUALITY | - |
dc.subject.keywordAuthor | Partial discharges | - |
dc.subject.keywordAuthor | Insulation | - |
dc.subject.keywordAuthor | Testing | - |
dc.subject.keywordAuthor | Stress | - |
dc.subject.keywordAuthor | Stator windings | - |
dc.subject.keywordAuthor | Voltage | - |
dc.subject.keywordAuthor | Voltage control | - |
dc.subject.keywordAuthor | Ac motors | - |
dc.subject.keywordAuthor | antennas | - |
dc.subject.keywordAuthor | fault diagnostics | - |
dc.subject.keywordAuthor | impulse testing | - |
dc.subject.keywordAuthor | insulation testing | - |
dc.subject.keywordAuthor | partial discharge | - |
dc.subject.keywordAuthor | stator winding insulation | - |
dc.subject.keywordAuthor | variable frequency drives | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.