Surface Functionalization of Enzyme-Coronated Gold Nanoparticles with an Erythrocyte Membrane for Highly Selective Glucose Assays
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jang, Jae Won | - |
dc.contributor.author | Kim, Hyunji | - |
dc.contributor.author | Kim, Insu | - |
dc.contributor.author | Lee, Sang Won | - |
dc.contributor.author | Jung, Hyo Gi | - |
dc.contributor.author | Hwang, Kyo Seon | - |
dc.contributor.author | Lee, Jeong Hoon | - |
dc.contributor.author | Lee, Gyudo | - |
dc.contributor.author | Lee, Dongtak | - |
dc.contributor.author | Yoon, Dae Sung | - |
dc.date.accessioned | 2022-06-09T13:40:55Z | - |
dc.date.available | 2022-06-09T13:40:55Z | - |
dc.date.created | 2022-06-09 | - |
dc.date.issued | 2022-05-03 | - |
dc.identifier.issn | 0003-2700 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/141738 | - |
dc.description.abstract | Colorimetric glucose sensors using enzyme coronated gold nanoparticles have been developed for high-throughput assays to monitor the blood glucose levels of diabetic patients. Although those sensors have shown sensitivity and wide linear detection ranges, they suffer from poor selectivity and stability in detecting blood glucose, which has limited their practical use. To address this limitation, herein, we functionalized glucose-oxidase-coronated gold nanoparticles with an erythrocyte membrane (EM-GOx-GNPs). Because the erythrocyte membrane (EM) selectively facilitates the permeation of glucose via glucose transporter-1 (GLUT1), the functionalization of GOx-GNPs with EM improved the stability, selectivity (3.3- to 15.8-fold higher), and limit of detection (LOD). Both membrane proteins, GLUT1 and aquaporin-1 (AQP1), on EM were shown to be key components for selective glucose detection by treatment with their inhibitors. Moreover, we demonstrated the stability of EM-GOx-GNPs in high-antioxidant-concentration conditions, under long-term storage (similar to 4 weeks) and a freeze-thaw cycle. Selectivity of the EM-GOx-GNPs against other saccharides was increased, which improved the LOD in phosphate-buffered saline and human serum. Our results indicated that the functionalization of colorimetric glucose sensors with EM is beneficial for improving selectivity and stability, which may make them candidates for use in a practical glucose sensor. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | AMER CHEMICAL SOC | - |
dc.subject | CRYSTAL-STRUCTURE | - |
dc.subject | OXIDASE | - |
dc.subject | SENSOR | - |
dc.subject | AGGREGATION | - |
dc.subject | PEROXIDASE | - |
dc.subject | MECHANISM | - |
dc.subject | ANGSTROM | - |
dc.subject | DISEASE | - |
dc.title | Surface Functionalization of Enzyme-Coronated Gold Nanoparticles with an Erythrocyte Membrane for Highly Selective Glucose Assays | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Gyudo | - |
dc.identifier.doi | 10.1021/acs.analchem.1c04541 | - |
dc.identifier.scopusid | 2-s2.0-85128805529 | - |
dc.identifier.wosid | 000795715700009 | - |
dc.identifier.bibliographicCitation | ANALYTICAL CHEMISTRY, v.94, no.17, pp.6473 - 6481 | - |
dc.relation.isPartOf | ANALYTICAL CHEMISTRY | - |
dc.citation.title | ANALYTICAL CHEMISTRY | - |
dc.citation.volume | 94 | - |
dc.citation.number | 17 | - |
dc.citation.startPage | 6473 | - |
dc.citation.endPage | 6481 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.subject.keywordPlus | CRYSTAL-STRUCTURE | - |
dc.subject.keywordPlus | OXIDASE | - |
dc.subject.keywordPlus | SENSOR | - |
dc.subject.keywordPlus | AGGREGATION | - |
dc.subject.keywordPlus | PEROXIDASE | - |
dc.subject.keywordPlus | MECHANISM | - |
dc.subject.keywordPlus | ANGSTROM | - |
dc.subject.keywordPlus | DISEASE | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.