Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Clinical Implications of Atrial Fibrillation Detection Using Wearable Devices in Patients With Cryptogenic Stroke (CANDLE-AF) Trial: Design and Rationale

Full metadata record
DC Field Value Language
dc.contributor.authorJung, Sodam-
dc.contributor.authorLee, Hye Ah-
dc.contributor.authorKang, In Sook-
dc.contributor.authorShin, Sang Hoon-
dc.contributor.authorChang, Yoonkyung-
dc.contributor.authorWoo Shin, Dong-
dc.contributor.authorPark, Moo-Seok-
dc.contributor.authorKim, Young Dae-
dc.contributor.authorNam, Hyo Suk-
dc.contributor.authorHeo, Ji Hoe-
dc.contributor.authorKim, Tae-Hoon-
dc.contributor.authorYu, Hee Tae-
dc.contributor.authorLee, Jung Myung-
dc.contributor.authorHeo, Sung Hyuk-
dc.contributor.authorWoo, Ho Geol-
dc.contributor.authorPark, Jin-Kyu-
dc.contributor.authorRoh, Seung-Young-
dc.contributor.authorKim, Chi Kyung-
dc.contributor.authorLee, Young-Soo-
dc.contributor.authorDo, Jin Kuk-
dc.contributor.authorKim, Dong-Hyeok-
dc.contributor.authorSong, Tae-Jin-
dc.contributor.authorPark, Junbeom-
dc.date.accessioned2022-06-10T11:40:18Z-
dc.date.available2022-06-10T11:40:18Z-
dc.date.created2022-06-10-
dc.date.issued2022-04-04-
dc.identifier.issn2297-055X-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/141845-
dc.description.abstractBackground: Although many electrocardiography wearable devices have been released recently for the detection of atrial fibrillation (AF), there are few studies reporting prospective data for wearable devices compared to the strategy of the existing guidelines in the detection of atrial fibrillation (AF) after cryptogenic stroke. A tiny single-patch monitor is more convenient than a conventional Holter monitor recording device and, therefore, longer duration of monitoring may be acceptable.& nbsp;& nbsp;Methods and Design: The CANDLE-AF study is a multicenter, prospective, randomized controlled trial. Patients with transient ischemic attack or ischemic stroke without any history of AF will be enrolled. The superiority of the 72-h single-patch monitor to standard strategy and non-inferiority of the 72-h single-patch monitor to an event-recorder-type device will be investigated. Single-patch monitor arm will repeat monitoring at 1, 3, 6, and 12 months, event-recorder-type arm will repeat monitoring twice daily for 12 months. The enrollment goal is a total of 600 patients, and the primary outcome is the detection of AF which continues at least 30 s during study period. The secondary outcome is the rate of changes from antiplatelet to anticoagulant and major adverse cardiac and cerebrovascular events within 1 year.& nbsp;Conclusions: The results of CANDLE-AF will clarify the role of a single-lead patch ECG for the early detection of AF in patients with acute ischemic stroke. In addition, the secondary outcome will be analyzed to determine whether more sensitive AF detection can affect the prognosis and if further device development is meaningful. ( KCT0005592).-
dc.languageEnglish-
dc.language.isoen-
dc.publisherFRONTIERS MEDIA SA-
dc.subjectACUTE ISCHEMIC-STROKE-
dc.subjectMONITORING STRATEGIES-
dc.subjectRISK-FACTORS-
dc.subjectOPEN-LABEL-
dc.subjectSCREEN-
dc.titleClinical Implications of Atrial Fibrillation Detection Using Wearable Devices in Patients With Cryptogenic Stroke (CANDLE-AF) Trial: Design and Rationale-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Chi Kyung-
dc.identifier.doi10.3389/fcvm.2022.837958-
dc.identifier.scopusid2-s2.0-85137147001-
dc.identifier.wosid000790963000001-
dc.identifier.bibliographicCitationFRONTIERS IN CARDIOVASCULAR MEDICINE, v.9-
dc.relation.isPartOfFRONTIERS IN CARDIOVASCULAR MEDICINE-
dc.citation.titleFRONTIERS IN CARDIOVASCULAR MEDICINE-
dc.citation.volume9-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaCardiovascular System & Cardiology-
dc.relation.journalWebOfScienceCategoryCardiac & Cardiovascular Systems-
dc.subject.keywordPlusACUTE ISCHEMIC-STROKE-
dc.subject.keywordPlusMONITORING STRATEGIES-
dc.subject.keywordPlusOPEN-LABEL-
dc.subject.keywordPlusRISK-FACTORS-
dc.subject.keywordPlusSCREEN-
dc.subject.keywordAuthoratrial fibrillation-
dc.subject.keywordAuthorcryptogenic stroke-
dc.subject.keywordAuthorischemic stroke-
dc.subject.keywordAuthorrhythm monitoring-
dc.subject.keywordAuthorsingle-lead ECG-
dc.subject.keywordAuthorwearable device-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE