Ultra-low-dose intraoperative X-ray imager for minimally invasive surgery: a pilot imaging study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Park, Haewook | - |
dc.contributor.author | Han, Kook Nam | - |
dc.contributor.author | Choi, Byeong Hyeon | - |
dc.contributor.author | Yoon, Hyunsuk | - |
dc.contributor.author | An, Hyun Joon | - |
dc.contributor.author | Lee, Jae Sung | - |
dc.contributor.author | Kim, Hyun Koo | - |
dc.date.accessioned | 2022-06-12T14:40:51Z | - |
dc.date.available | 2022-06-12T14:40:51Z | - |
dc.date.created | 2022-06-09 | - |
dc.date.issued | 2022-04 | - |
dc.identifier.issn | 2226-4477 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/142148 | - |
dc.description.abstract | Background: With advances in surgical technology, thoracic surgeons have widely adopted minimally invasive limited-resection techniques to preserve normal tissues. However, it remains difficult to achieve in situ localization of invisible pulmonary nodules during surgery. Therefore, we proposed an in situ ultra-low-dose X-ray imaging device for intraoperative pulmonary nodule localization during minimally invasive surgeries. Methods: The proposed device features a hand-held type and consists of a carbon nanotube-based X-ray source and an intraoral dental sensor. In a preclinical study, we created pseudo pulmonary nodules using ex vivo pig lungs. Subsequently, its clinical feasibility was evaluated using ex vivo lung cancer specimens from patients with cancer who had undergone minimally invasive surgery. Results: Using the proposed device, we successfully differentiated normal and abnormal tissues from X-ray images of resected lung specimens. In addition, our proposed device only yielded an average radiation dose of 90.9 nGy for a single acquisition of X-ray images and demonstrated excellent temperature stability under consecutive X-ray irradiations. The radiation exposure of our proposed device (0.1 +/- 0.0006 mu Sv/h) was significantly lower than that of conventional C-arm fluoroscopy (41.5 +/- 51.8 mu Sv/h). In both preclinical and clinical studies, the margin of nodule shadows was clearly visualized using the proposed device. Conclusions: The proposed device substantially reduced radiation exposure to staff and patients and may allow in situ localization of pulmonary nodules. Our proposed device clearly revealed the margins of lung nodules with radiocontrast injection and showed the potential to identify solid nodules without the use of radiocontrast agents. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | AME PUBL CO | - |
dc.subject | PULMONARY NODULE LOCALIZATION | - |
dc.subject | CELL LUNG-CANCER | - |
dc.subject | CONE-BEAM CT | - |
dc.subject | COMPUTED-TOMOGRAPHY | - |
dc.subject | MICROCOIL LOCALIZATION | - |
dc.subject | SUBLOBAR RESECTION | - |
dc.subject | NEEDLE-BIOPSY | - |
dc.subject | FLUORESCENCE | - |
dc.subject | FEASIBILITY | - |
dc.subject | LOBECTOMY | - |
dc.title | Ultra-low-dose intraoperative X-ray imager for minimally invasive surgery: a pilot imaging study | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Hyun Koo | - |
dc.identifier.doi | 10.21037/tlcr-21-909 | - |
dc.identifier.scopusid | 2-s2.0-85129443264 | - |
dc.identifier.wosid | 000791519200001 | - |
dc.identifier.bibliographicCitation | TRANSLATIONAL LUNG CANCER RESEARCH, v.11, no.4, pp.588 - 599 | - |
dc.relation.isPartOf | TRANSLATIONAL LUNG CANCER RESEARCH | - |
dc.citation.title | TRANSLATIONAL LUNG CANCER RESEARCH | - |
dc.citation.volume | 11 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 588 | - |
dc.citation.endPage | 599 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Oncology | - |
dc.relation.journalResearchArea | Respiratory System | - |
dc.relation.journalWebOfScienceCategory | Oncology | - |
dc.relation.journalWebOfScienceCategory | Respiratory System | - |
dc.subject.keywordPlus | PULMONARY NODULE LOCALIZATION | - |
dc.subject.keywordPlus | CELL LUNG-CANCER | - |
dc.subject.keywordPlus | CONE-BEAM CT | - |
dc.subject.keywordPlus | COMPUTED-TOMOGRAPHY | - |
dc.subject.keywordPlus | MICROCOIL LOCALIZATION | - |
dc.subject.keywordPlus | SUBLOBAR RESECTION | - |
dc.subject.keywordPlus | NEEDLE-BIOPSY | - |
dc.subject.keywordPlus | FLUORESCENCE | - |
dc.subject.keywordPlus | FEASIBILITY | - |
dc.subject.keywordPlus | LOBECTOMY | - |
dc.subject.keywordAuthor | Ultra-low-dose | - |
dc.subject.keywordAuthor | X-ray imaging | - |
dc.subject.keywordAuthor | minimally invasive surgery | - |
dc.subject.keywordAuthor | lung cancer | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.