Interfacial shear resistance of angle shear connectors welded to concrete filled U-shaped CFS beam
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Oh, Hyoung Seok | - |
dc.contributor.author | Shin, Hyeongyeop | - |
dc.contributor.author | Ju, Youngkyu | - |
dc.contributor.author | Kang, Thomas H. -K. | - |
dc.date.accessioned | 2022-06-22T12:41:03Z | - |
dc.date.available | 2022-06-22T12:41:03Z | - |
dc.date.created | 2022-06-22 | - |
dc.date.issued | 2022-05-10 | - |
dc.identifier.issn | 1229-9367 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/142260 | - |
dc.description.abstract | For multi-story structural systems, Korean steel industry has fostered development of a steel-concrete composite beam. Configuration of the composite beam is characterized by steel angle shear connectors welded to a U-shaped cold formed-steel beam. Effects of shear connector orientation and spacing were studied to evaluate current application of the angle shear connector design equation in AC495. For the study, interfacial shear resistance behavior was investigated by conducting 24 push-out tests and attuned using unreinforced push-out specimens. Interfacial shear to horizontal slip response was reported along with corresponding failure patterns. Pure shear connector strength was also evaluated by excluding concrete shear contribution, which was estimated in relation to steel beam-slab interface separation or interfacial crack width. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | TECHNO-PRESS | - |
dc.subject | BEHAVIOR | - |
dc.subject | SLAB | - |
dc.title | Interfacial shear resistance of angle shear connectors welded to concrete filled U-shaped CFS beam | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Ju, Youngkyu | - |
dc.identifier.doi | 10.12989/scs.2022.43.3.311 | - |
dc.identifier.scopusid | 2-s2.0-85133687358 | - |
dc.identifier.wosid | 000803773700003 | - |
dc.identifier.bibliographicCitation | STEEL AND COMPOSITE STRUCTURES, v.43, no.3, pp.311 - 325 | - |
dc.relation.isPartOf | STEEL AND COMPOSITE STRUCTURES | - |
dc.citation.title | STEEL AND COMPOSITE STRUCTURES | - |
dc.citation.volume | 43 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 311 | - |
dc.citation.endPage | 325 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Construction & Building Technology | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Materials Science | - |
dc.relation.journalWebOfScienceCategory | Construction & Building Technology | - |
dc.relation.journalWebOfScienceCategory | Engineering, Civil | - |
dc.relation.journalWebOfScienceCategory | Materials Science, Composites | - |
dc.subject.keywordPlus | BEHAVIOR | - |
dc.subject.keywordPlus | SLAB | - |
dc.subject.keywordAuthor | aggregate interlocking resistance | - |
dc.subject.keywordAuthor | angle | - |
dc.subject.keywordAuthor | channel | - |
dc.subject.keywordAuthor | cold formed-steel | - |
dc.subject.keywordAuthor | composite beam | - |
dc.subject.keywordAuthor | concrete | - |
dc.subject.keywordAuthor | interfacial shear strength | - |
dc.subject.keywordAuthor | push-out test | - |
dc.subject.keywordAuthor | shear connector | - |
dc.subject.keywordAuthor | U-shaped section | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.