Development of practical allocation method for reactive power reference for wind farms through inner-voltage restriction
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Yoo, Yeuntae | - |
dc.contributor.author | Jung, Seungmin | - |
dc.contributor.author | Song, Sungyoon | - |
dc.contributor.author | Suh, Jaewan | - |
dc.contributor.author | Lee, Jaehyeong | - |
dc.contributor.author | Jang, Gilsoo | - |
dc.date.accessioned | 2022-08-15T05:40:42Z | - |
dc.date.available | 2022-08-15T05:40:42Z | - |
dc.date.created | 2022-08-12 | - |
dc.date.issued | 2022-08 | - |
dc.identifier.issn | 1751-8687 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/143236 | - |
dc.description.abstract | This study considers the optimal reactive power dispatch strategy that minimizes electrical loss while working within the constraints of the internal layout voltage. Wind turbines (WTs) with a power converter system can promptly generate reactive power, and when a reactive power order arrives from the connected grid, an operator can assign a reactive power reference to each wind turbine. Recently, multiple objective functions in use have been based on centralized control, but their flexibility has been determined as inadequate for situations in which the voltage range of the wind turbine is also a factor. The designated constraints of the voltage fluctuation for each section have thus been considered by designing and applying an adaptive method. The main purpose of such a method is to use general dispatch optimization while maintaining the voltage of each connection point within operating range. The included case studies are designed using an electromagnetic transients program that checks both the voltage and loss of the entire wind farm. We tried to identify voltage violations and confirmed the effectiveness of the proposed method. This work thus attempts to confirm whether an objective function can be implemented while also adhering to a certain grid code. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | INST ENGINEERING TECHNOLOGY-IET | - |
dc.subject | MANAGEMENT | - |
dc.subject | DISPATCH | - |
dc.subject | CONVERTER | - |
dc.subject | FLOW | - |
dc.title | Development of practical allocation method for reactive power reference for wind farms through inner-voltage restriction | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Jang, Gilsoo | - |
dc.identifier.doi | 10.1049/gtd2.12499 | - |
dc.identifier.scopusid | 2-s2.0-85129287271 | - |
dc.identifier.wosid | 000790856000001 | - |
dc.identifier.bibliographicCitation | IET GENERATION TRANSMISSION & DISTRIBUTION, v.16, no.15, pp.3069 - 3079 | - |
dc.relation.isPartOf | IET GENERATION TRANSMISSION & DISTRIBUTION | - |
dc.citation.title | IET GENERATION TRANSMISSION & DISTRIBUTION | - |
dc.citation.volume | 16 | - |
dc.citation.number | 15 | - |
dc.citation.startPage | 3069 | - |
dc.citation.endPage | 3079 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.subject.keywordPlus | MANAGEMENT | - |
dc.subject.keywordPlus | DISPATCH | - |
dc.subject.keywordPlus | CONVERTER | - |
dc.subject.keywordPlus | FLOW | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.