Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

CO2 emissions and energy performance analysis of ground-source and solar-assisted ground-source heat pumps using low-GWP refrigerants

Full metadata record
DC Field Value Language
dc.contributor.authorLee, M.-
dc.contributor.authorKim, J.-
dc.contributor.authorShin, H.H.-
dc.contributor.authorCho, W.-
dc.contributor.authorKim, Y.-
dc.date.accessioned2022-10-06T20:41:35Z-
dc.date.available2022-10-06T20:41:35Z-
dc.date.created2022-10-06-
dc.date.issued2022-12-
dc.identifier.issn0360-5442-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/144155-
dc.description.abstractThe energy consumption and CO2 emissions of heat pump systems can be reduced effectively by adopting an appropriate alternative refrigerant. However, investigation on alternative refrigerants for ground-source heat pump (GSHP) and solar-assisted ground-source heat pump (SGSHP) systems is limited although these systems still use conventional refrigerants. In this study, the life cycle climate performance (LCCP) and primary energy consumption (PEC) for GSHP and SGSHP systems using conventional and alternative refrigerants are compared to those for conventional boiler systems. Experiments are conducted to investigate the heating performance of selected refrigerants. For regions with low CO2 emission conversion factor for electricity (μCO2.elec), GSHP systems using R1234yf are the most suitable considering the LCCP, owing to its low GWP and high performance. However, SGSHP systems using R134a with a large system size are preferred in regions with high μCO2.elec, because system efficiency takes the priority in reducing the LCCP. For PEC, SGSHP systems using R134a are recommended owing to its high efficiency. However, in regions where oil or natural gas is used dominantly, either the system size of SGSHPs should be increased or the primary energy conversion factor of electricity should be reduced to guarantee the benefits of PEC reduction of SGSHP systems. © 2022 Elsevier Ltd-
dc.languageEnglish-
dc.language.isoen-
dc.publisherElsevier Ltd-
dc.titleCO2 emissions and energy performance analysis of ground-source and solar-assisted ground-source heat pumps using low-GWP refrigerants-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Y.-
dc.identifier.doi10.1016/j.energy.2022.125198-
dc.identifier.scopusid2-s2.0-85136536102-
dc.identifier.wosid000863074800002-
dc.identifier.bibliographicCitationEnergy, v.261-
dc.relation.isPartOfEnergy-
dc.citation.titleEnergy-
dc.citation.volume261-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaThermodynamics-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalWebOfScienceCategoryThermodynamics-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.subject.keywordPlusCYCLE CLIMATE PERFORMANCE-
dc.subject.keywordPlusDESIGN-
dc.subject.keywordPlusLCCP-
dc.subject.keywordPlusOPTIONS-
dc.subject.keywordPlusR1234ZE(E)-
dc.subject.keywordPlusR134A-
dc.subject.keywordPlusSTORAGE-
dc.subject.keywordPlusSYSTEMS-
dc.subject.keywordAuthorBoiler system-
dc.subject.keywordAuthorGround-source heat pump-
dc.subject.keywordAuthorLife cycle climate performance-
dc.subject.keywordAuthorPrimary energy consumption-
dc.subject.keywordAuthorSolar-assisted ground-source heat pump-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher KIM, Yong Chan photo

KIM, Yong Chan
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE