Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of Laser and Conventional Lancing Devices for Blood Glucose Measurement Conformance and Patient Satisfaction in Diabetes Mellitus

Full metadata record
DC Field Value Language
dc.contributor.authorKim Jung A-
dc.contributor.author박민정-
dc.contributor.authorEyun Song-
dc.contributor.author노은-
dc.contributor.author박소영-
dc.contributor.author이다영-
dc.contributor.author김재영-
dc.contributor.author유지희-
dc.contributor.author서지아-
dc.contributor.author최경묵-
dc.contributor.author백세현-
dc.contributor.author류혜진-
dc.contributor.author김난희-
dc.date.accessioned2022-12-09T03:00:10Z-
dc.date.available2022-12-09T03:00:10Z-
dc.date.created2022-12-09-
dc.date.issued2022-11-
dc.identifier.issn2233-6079-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/146546-
dc.description.abstractSelf-monitoring of capillary blood glucose is important for controlling diabetes. Recently, a laser lancing device (LMT-1000) that can collect capillary blood without skin puncture was developed. We enrolled 150 patients with type 1 or 2 diabetes mellitus. Blood sampling was performed on the same finger on each hand using the LMT-1000 or a conventional lancet. The primary outcome was correlation between glucose values using the LMT-1000 and that using a lancet. And we compared the pain and satisfaction of the procedures. The capillary blood sampling success rates with the LMT-1000 and lancet were 99.3% and 100%, respectively. There was a positive correlation (r=0.974, <i>P</i><0.001) between mean blood glucose levels in the LMT-1000 (175.8±63.0 mg/dL) and conventional lancet samples (172.5±63.6 mg/dL). LMT-1000 reduced puncture pain by 75.0% and increased satisfaction by 80.0% compared to a lancet. We demonstrated considerable consistency in blood glucose measurements between samples from the LMT-1000 and a lancet, but improved satisfaction and clinically significant pain reduction were observed with the LMT-1000 compared to those with a lancet.-
dc.languageEnglish-
dc.language.isoen-
dc.publisher대한당뇨병학회-
dc.titleComparison of Laser and Conventional Lancing Devices for Blood Glucose Measurement Conformance and Patient Satisfaction in Diabetes Mellitus-
dc.title.alternativeComparison of Laser and Conventional Lancing Devices for Blood Glucose Measurement Conformance and Patient Satisfaction in Diabetes Mellitus-
dc.typeArticle-
dc.contributor.affiliatedAuthor김난희-
dc.identifier.doi10.4093/dmj.2021.0293-
dc.identifier.bibliographicCitationDiabetes and Metabolism Journal, v.46, no.6, pp.936 - 940-
dc.relation.isPartOfDiabetes and Metabolism Journal-
dc.citation.titleDiabetes and Metabolism Journal-
dc.citation.volume46-
dc.citation.number6-
dc.citation.startPage936-
dc.citation.endPage940-
dc.type.rimsART-
dc.identifier.kciidART002899911-
dc.description.journalClass1-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorBlood glucose self-monitoring-
dc.subject.keywordAuthorDiabetes mellitus-
dc.subject.keywordAuthorLasers-
dc.subject.keywordAuthorPain-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Nan Hee photo

Kim, Nan Hee
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE