Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Cycle performance analysis and experimental validation of a novel diffusion absorption refrigeration system using R600a/n-octane

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Gawon-
dc.contributor.authorChoi, Hyung Won-
dc.contributor.authorKang, Yong Tae-
dc.date.accessioned2021-08-30T02:59:54Z-
dc.date.available2021-08-30T02:59:54Z-
dc.date.created2021-06-18-
dc.date.issued2021-02-15-
dc.identifier.issn0360-5442-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/49582-
dc.description.abstractDiffusion absorption refrigeration (DAR) is a promising cycle with regard to renewable energy utilization, as the cycle can operate using only a thermal energy input. This study focuses on the application of a low global warming potential (GWP) refrigerant as a substitution for conventional ammonia refrigerant. In this study, R600a/n-octane is chosen as a novel refrigerant/absorbent pair for DAR. The cycle operation characteristics are investigated through numerical analysis, in terms of the coefficient of performance (COP) and minimum temperature. The influences of five key parameters (driving temperature, total pressure, evaporator temperature, absorber effectiveness, and solution heat exchanger effectiveness) on the COP are also analyzed. Furthermore, additional experiments are performed to validate the simulation results through comparisons with the experimental data. The variation trend of the COP shows good agreement between the simulations and experiments, and the mathematical model provides a reasonable estimation of the maximum COP. It is concluded that R600a/n-octane has significant potential for DAR application, as a maximum COP of 0.162 is achieved at a driving temperature of approximately 100 degrees C, making it more favorable than other low-GWP refrigerant working fluids pairs and applicable for solar cooling. (C) 2020 Elsevier Ltd. All rights reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.subjectWORKING-
dc.subjectAMMONIA-
dc.subjectDRIVEN-
dc.subjectWATER-
dc.titleCycle performance analysis and experimental validation of a novel diffusion absorption refrigeration system using R600a/n-octane-
dc.typeArticle-
dc.contributor.affiliatedAuthorKang, Yong Tae-
dc.identifier.doi10.1016/j.energy.2020.119328-
dc.identifier.scopusid2-s2.0-85096513418-
dc.identifier.wosid000611853500001-
dc.identifier.bibliographicCitationENERGY, v.217-
dc.relation.isPartOfENERGY-
dc.citation.titleENERGY-
dc.citation.volume217-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaThermodynamics-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalWebOfScienceCategoryThermodynamics-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.subject.keywordPlusWORKING-
dc.subject.keywordPlusAMMONIA-
dc.subject.keywordPlusDRIVEN-
dc.subject.keywordPlusWATER-
dc.subject.keywordAuthorCOP-
dc.subject.keywordAuthorDiffusion absorption refrigeration (DAR)-
dc.subject.keywordAuthorLow-GWP refrigerant-
dc.subject.keywordAuthorMinimum temperature-
dc.subject.keywordAuthorPerformance analysis-
dc.subject.keywordAuthorR600a-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kang, Yong Tae photo

Kang, Yong Tae
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE