Detailed Information

Cited 0 time in webofscience Cited 1 time in scopus
Metadata Downloads

Optical coherence tomography-based machine learning for predicting fractional flow reserve in intermediate coronary stenosis: a feasibility study

Full metadata record
DC Field Value Language
dc.contributor.authorCha, Jung-Joon-
dc.contributor.authorTran Dinh Son-
dc.contributor.authorHa, Jinyong-
dc.contributor.authorKim, Jung-Sun-
dc.contributor.authorHong, Sung-Jin-
dc.contributor.authorAhn, Chul-Min-
dc.contributor.authorKim, Byeong-Keuk-
dc.contributor.authorKo, Young-Guk-
dc.contributor.authorChoi, Donghoon-
dc.contributor.authorHong, Myeong-Ki-
dc.contributor.authorJang, Yangsoo-
dc.date.accessioned2021-08-30T05:20:49Z-
dc.date.available2021-08-30T05:20:49Z-
dc.date.created2021-06-18-
dc.date.issued2020-12-24-
dc.identifier.issn2045-2322-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/50773-
dc.description.abstractMachine learning approaches using intravascular optical coherence tomography (OCT) to predict fractional flow reserve (FFR) have not been investigated. Both OCT and FFR data were obtained for left anterior descending artery lesions in 125 patients. Training and testing groups were partitioned in the ratio of 5:1. The OCT-based machine learning-FFR was derived for the testing group and compared with wire-based FFR in terms of ischemia diagnosis (FFR <= 0.8). The OCT-based machine learning-FFR showed good correlation (r=0.853, P<0.001) with the wire-based FFR. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of the OCT-based machine learning-FFR for the testing group were 100%, 92.9%, 87.5%, 100%, and 95.2%, respectively. The OCT-based machine learning-FFR can be used to simultaneously acquire information on both image and functional modalities using one procedure, suggesting that it may provide optimized treatments for intermediate coronary artery stenosis.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherNATURE RESEARCH-
dc.subjectINTRAVASCULAR ULTRASOUND-
dc.subjectDIAGNOSTIC-ACCURACY-
dc.subjectANGIOGRAPHY-
dc.subjectMANAGEMENT-
dc.subjectPLAQUE-
dc.subjectPCI-
dc.subjectOCT-
dc.titleOptical coherence tomography-based machine learning for predicting fractional flow reserve in intermediate coronary stenosis: a feasibility study-
dc.typeArticle-
dc.contributor.affiliatedAuthorCha, Jung-Joon-
dc.identifier.doi10.1038/s41598-020-77507-y-
dc.identifier.scopusid2-s2.0-85096547276-
dc.identifier.wosid000596278900006-
dc.identifier.bibliographicCitationSCIENTIFIC REPORTS, v.10, no.1-
dc.relation.isPartOfSCIENTIFIC REPORTS-
dc.citation.titleSCIENTIFIC REPORTS-
dc.citation.volume10-
dc.citation.number1-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.subject.keywordPlusINTRAVASCULAR ULTRASOUND-
dc.subject.keywordPlusDIAGNOSTIC-ACCURACY-
dc.subject.keywordPlusANGIOGRAPHY-
dc.subject.keywordPlusMANAGEMENT-
dc.subject.keywordPlusPLAQUE-
dc.subject.keywordPlusPCI-
dc.subject.keywordPlusOCT-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE