Detailed Information

Cited 0 time in webofscience Cited 1 time in scopus
Metadata Downloads

High-Throughput Separation of Microvesicles from Whole Blood Components Using Viscoelastic Fluid

Full metadata record
DC Field Value Language
dc.contributor.authorNam, Jeonghun-
dc.contributor.authorYoon, Jung-
dc.contributor.authorJee, Hyunseul-
dc.contributor.authorJang, Woong Sik-
dc.contributor.authorLim, Chae Seung-
dc.date.accessioned2021-08-30T06:43:58Z-
dc.date.available2021-08-30T06:43:58Z-
dc.date.created2021-06-19-
dc.date.issued2020-12-
dc.identifier.issn2365-709X-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/51300-
dc.description.abstractCell-derived microvesicles (MVs, also known as microparticles, MPs) are known as important biomarkers of various diseases including cardiovascular diseases, infectious diseases, and cancer. Development of techniques for blood cell removal and MV isolation is required for downstream analyses in biological and clinical applications. A sheathless, label-free, viscoelastic microfluidic device is proposed for the separation of submicrometer platelet-derived MPs (PDMPs) from whole blood. Flow rate and channel length dependent performance of the device is evaluated using 2-mu m particles as analogs to platelets and hematocrit (Hct) dependent flow characteristics of red blood cells (RBCs) are observed. In addition, the removal rate of nanoparticles of sizes 300, 500, 700, and 1000 nm is evaluated, and finally, the device is applied to examine the recovery of PDMPs from diluted whole blood sample. At Q = 200 mu L min(-1) in a 15-mm long microchannel, RBCs at 5% Hct and platelets are removed to the central outlet without platelet activation, while PDMPs are successfully isolated to the side outlets within approximate to 2 min. The PDMPs collected from the device are analyzed by flow cytometry. The device exhibits approximate to 4.8-fold enhanced isolation performance compared to the centrifugation method.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherWILEY-
dc.subjectPLATELET-DERIVED MICROPARTICLES-
dc.subjectFLOW-CYTOMETRY-
dc.subjectCIRCULATING MICROPARTICLES-
dc.subjectPARTICLE MIGRATION-
dc.subjectEXTRACELLULAR VESICLES-
dc.subjectINTERNATIONAL SOCIETY-
dc.subjectCALIBRATED BEADS-
dc.subjectSMART PIPETTE-
dc.subjectSHEAR-STRESS-
dc.subjectSTANDARDIZATION-
dc.titleHigh-Throughput Separation of Microvesicles from Whole Blood Components Using Viscoelastic Fluid-
dc.typeArticle-
dc.contributor.affiliatedAuthorYoon, Jung-
dc.contributor.affiliatedAuthorLim, Chae Seung-
dc.identifier.doi10.1002/admt.202000612-
dc.identifier.scopusid2-s2.0-85096696594-
dc.identifier.wosid000587346500001-
dc.identifier.bibliographicCitationADVANCED MATERIALS TECHNOLOGIES, v.5, no.12-
dc.relation.isPartOfADVANCED MATERIALS TECHNOLOGIES-
dc.citation.titleADVANCED MATERIALS TECHNOLOGIES-
dc.citation.volume5-
dc.citation.number12-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaMaterials Science-
dc.relation.journalWebOfScienceCategoryMaterials Science, Multidisciplinary-
dc.subject.keywordPlusPLATELET-DERIVED MICROPARTICLES-
dc.subject.keywordPlusFLOW-CYTOMETRY-
dc.subject.keywordPlusCIRCULATING MICROPARTICLES-
dc.subject.keywordPlusPARTICLE MIGRATION-
dc.subject.keywordPlusEXTRACELLULAR VESICLES-
dc.subject.keywordPlusINTERNATIONAL SOCIETY-
dc.subject.keywordPlusCALIBRATED BEADS-
dc.subject.keywordPlusSMART PIPETTE-
dc.subject.keywordPlusSHEAR-STRESS-
dc.subject.keywordPlusSTANDARDIZATION-
dc.subject.keywordAuthorisolation-
dc.subject.keywordAuthorplatelet&amp-
dc.subject.keywordAuthor#8208-
dc.subject.keywordAuthorderived microparticles-
dc.subject.keywordAuthorquantification-
dc.subject.keywordAuthorsubmicrometer particles-
dc.subject.keywordAuthorviscoelastic fluids-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Chae Seung photo

Lim, Chae Seung
의과학과
Read more

Altmetrics

Total Views & Downloads

BROWSE