Normal-incidence type solution immersed silicon (SIS) biosensor for ultra-sensitive, label-free detection of cardiac troponin I
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Dong Hyung | - |
dc.contributor.author | Chegal, Won | - |
dc.contributor.author | Cho, Yong Jai | - |
dc.contributor.author | O, Sang Won | - |
dc.contributor.author | Le, Long Van | - |
dc.contributor.author | Diware, Mangesh S. | - |
dc.contributor.author | Paek, Se-Hwan | - |
dc.contributor.author | Kim, Young Dong | - |
dc.contributor.author | Cho, Hyun Mo | - |
dc.date.accessioned | 2021-08-30T08:41:18Z | - |
dc.date.available | 2021-08-30T08:41:18Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2020-11-15 | - |
dc.identifier.issn | 0956-5663 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/51501 | - |
dc.description.abstract | Early diagnosis of acute myocardial infarction (AMI) significantly reduce the mortality rate and can be achieved via high-sensitive detection of AMI specific cardiac troponin I (cTnI) biomarker. Here, we present normal-incident type solution-immersed silicon (NI-SIS) ellipsometric biosensor, designed for ultra-high sensitive, high-throughput, label-free detection of the target protein. The NI-SIS sensors are equipped with a specially designed prism that maintains the angle of incidence close to the Brewster angle during operation, which significantly reduces SIS noise signals induced by the refractive index fluctuations of the surrounding medium, improves the signal-to-noise ratio, in-results lowers the detection limit. We applied NI-SIS biosensor for ultra-sensitive detection of cTnI biomarkers in human serum. The optimized sensor chip fabrication and detection operation procedures are proposed. The wide linear concentration ranges of fg/mL to ng/mL is achieved with the detection limit of 22.0 fg/mL of cTnI. The analytical correlation was assessed by linear regression analysis with the results of the Pathfast reference system. These impressive biosensing capabilities of NI-SIS technology have huge potentials for accurate detection of target species in different application areas, such as diagnosis, drug discovery, and food contaminations. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER ADVANCED TECHNOLOGY | - |
dc.subject | THIN-FILMS | - |
dc.subject | COMPANION DIAGNOSTICS | - |
dc.subject | REFRACTIVE-INDEX | - |
dc.subject | PERFORMANCE | - |
dc.subject | ELLIPSOMETRY | - |
dc.subject | BIOMARKERS | - |
dc.subject | BLOCKING | - |
dc.subject | SEQUENCE | - |
dc.subject | SIGNAL | - |
dc.subject | SERUM | - |
dc.title | Normal-incidence type solution immersed silicon (SIS) biosensor for ultra-sensitive, label-free detection of cardiac troponin I | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Paek, Se-Hwan | - |
dc.identifier.doi | 10.1016/j.bios.2020.112525 | - |
dc.identifier.scopusid | 2-s2.0-85089727456 | - |
dc.identifier.wosid | 000574929400003 | - |
dc.identifier.bibliographicCitation | BIOSENSORS & BIOELECTRONICS, v.168 | - |
dc.relation.isPartOf | BIOSENSORS & BIOELECTRONICS | - |
dc.citation.title | BIOSENSORS & BIOELECTRONICS | - |
dc.citation.volume | 168 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Biophysics | - |
dc.relation.journalResearchArea | Biotechnology & Applied Microbiology | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Electrochemistry | - |
dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
dc.relation.journalWebOfScienceCategory | Biophysics | - |
dc.relation.journalWebOfScienceCategory | Biotechnology & Applied Microbiology | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalWebOfScienceCategory | Electrochemistry | - |
dc.relation.journalWebOfScienceCategory | Nanoscience & Nanotechnology | - |
dc.subject.keywordPlus | THIN-FILMS | - |
dc.subject.keywordPlus | COMPANION DIAGNOSTICS | - |
dc.subject.keywordPlus | REFRACTIVE-INDEX | - |
dc.subject.keywordPlus | PERFORMANCE | - |
dc.subject.keywordPlus | ELLIPSOMETRY | - |
dc.subject.keywordPlus | BIOMARKERS | - |
dc.subject.keywordPlus | BLOCKING | - |
dc.subject.keywordPlus | SEQUENCE | - |
dc.subject.keywordPlus | SIGNAL | - |
dc.subject.keywordPlus | SERUM | - |
dc.subject.keywordAuthor | Solution immersed silicon | - |
dc.subject.keywordAuthor | Ellipsometry | - |
dc.subject.keywordAuthor | Normal-incidence prism | - |
dc.subject.keywordAuthor | Cardiac troponin I | - |
dc.subject.keywordAuthor | Myocardial infarction | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.