A simple reagent-less approach using electrical discharge as a substitution for chelating agent in addressing genomic assay inhibition by divalent cations
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Jin, Hyowon | - |
dc.contributor.author | Yoon, Yeomin | - |
dc.contributor.author | Liles, Mark R. | - |
dc.contributor.author | Chua, Beelee | - |
dc.contributor.author | Son, Ahjeong | - |
dc.date.accessioned | 2021-08-30T09:26:01Z | - |
dc.date.available | 2021-08-30T09:26:01Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2020-11-07 | - |
dc.identifier.issn | 0003-2654 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/51824 | - |
dc.description.abstract | Electrical discharge treatment was shown to be a viable substitution for chelating agent in genomic assays. Divalent cation Mg2+ inhibits the performance of DNA hybridization based genomic assays by binding to the DNA and disrupting DNA hybridization. Until now, chelating agents such as ethylenediaminetetraacetic acid (EDTA) was the only option to address the presence of Mg2+ in samples. However, EDTA is a well-known environmental contaminant. In this work, we successfully employed electrical discharge instead of EDTA to render Mg2+ insipid. Its preliminary efficacy was first observed via circular dichroism (CD) and zeta potential analyses. After electrical discharge treatment, the reduction in CD shift at 280 nm was significant for samples with 10(-3) and 10(-8) M Mg2+. The zeta potential of Mg2+ laden samples were also restored from -4.71 +/- 1.38 to -20.59 +/- 6.37 mV after electrical discharge treatment. Both CD shift and change in zeta potential suggested that 2 min of electrical discharge treatment could prevent Mg2+ from binding to DNA. The complete efficacy of electrical discharge treatment was demonstrated with the performance recovery (within similar to 15% of the control) of a genomic assay variant (NanoGene assay) while analyzing Mg2+ laden samples (10(-5)-10(-3) M). Assuming 10 million samples are analyzed annually, the proposed electrical discharge treatment (similar to 50 mW per sample) would allow us to trade environmental contamination by similar to 50 kg of hazardous EDTA with a single 250 W STC (standard test conditions) solar panel. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ROYAL SOC CHEMISTRY | - |
dc.subject | WATER | - |
dc.subject | QUANTIFICATION | - |
dc.subject | RESISTANT | - |
dc.subject | HYBRIDIZATION | - |
dc.subject | ORGANISMS | - |
dc.subject | MAGNESIUM | - |
dc.subject | SOILS | - |
dc.title | A simple reagent-less approach using electrical discharge as a substitution for chelating agent in addressing genomic assay inhibition by divalent cations | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Chua, Beelee | - |
dc.identifier.doi | 10.1039/d0an01666g | - |
dc.identifier.scopusid | 2-s2.0-85094684826 | - |
dc.identifier.wosid | 000582413100035 | - |
dc.identifier.bibliographicCitation | ANALYST, v.145, no.21, pp.6846 - 6858 | - |
dc.relation.isPartOf | ANALYST | - |
dc.citation.title | ANALYST | - |
dc.citation.volume | 145 | - |
dc.citation.number | 21 | - |
dc.citation.startPage | 6846 | - |
dc.citation.endPage | 6858 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.subject.keywordPlus | WATER | - |
dc.subject.keywordPlus | QUANTIFICATION | - |
dc.subject.keywordPlus | RESISTANT | - |
dc.subject.keywordPlus | HYBRIDIZATION | - |
dc.subject.keywordPlus | ORGANISMS | - |
dc.subject.keywordPlus | MAGNESIUM | - |
dc.subject.keywordPlus | SOILS | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.