Safety parameters of ferromagnetic device during thyroid surgery: Porcine model using continuous neuromonitoring
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Huang, Tzu-Yen | - |
dc.contributor.author | Lin, Yi-Chu | - |
dc.contributor.author | Tseng, Hsin-Yi | - |
dc.contributor.author | Dionigi, Gianlorenzo | - |
dc.contributor.author | Kim, Hoon Yub | - |
dc.contributor.author | Chai, Young Jun | - |
dc.contributor.author | Lu, I-Cheng | - |
dc.contributor.author | Chang, Pi-Ying | - |
dc.contributor.author | Chiang, Feng-Yu | - |
dc.contributor.author | Wu, Che-Wei | - |
dc.date.accessioned | 2021-08-30T13:49:24Z | - |
dc.date.available | 2021-08-30T13:49:24Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2020-10 | - |
dc.identifier.issn | 1043-3074 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/53020 | - |
dc.description.abstract | Background The ferromagnetic (FM) device is a new surgical energy modality. This study investigated dynamic recurrent laryngeal nerve (RLN) electromyographic (EMG) data to define safety parameters for using FM devices in thyroidectomy. Methods Real-time EMG tracings obtained under continuous neuromonitoring were recorded from 24 RLNs (12 piglets). In the activation study, FM devices were activated at varying distances from the RLN. In the cooling study, FM devices were cooled for varying time intervals, or muscle touch maneuver was performed, before contact with the RLN. Results During the FMwand/FMsealer activation, no adverse EMG events occurred at distances of 2 mm or longer. The cooling study revealed no adverse EMG events after 1-second (FMwand) or 3-second (FMsealer) intervals or after muscle touch maneuver. Conclusions An FM device should be activated at a distance of 2 mm from the RLN and should be adequately cooled before further contact with the RLN. Surgeons can avoid RLN injury by observing standard procedures for using FM devices. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | WILEY | - |
dc.subject | RECURRENT LARYNGEAL NERVE | - |
dc.subject | ENERGY-BASED DEVICES | - |
dc.subject | HARMONIC SCALPEL | - |
dc.subject | THERMAL-INJURY | - |
dc.subject | MECHANISMS | - |
dc.subject | FOCUS | - |
dc.title | Safety parameters of ferromagnetic device during thyroid surgery: Porcine model using continuous neuromonitoring | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Hoon Yub | - |
dc.identifier.doi | 10.1002/hed.26334 | - |
dc.identifier.scopusid | 2-s2.0-85087305339 | - |
dc.identifier.wosid | 000541542200001 | - |
dc.identifier.bibliographicCitation | HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, v.42, no.10, pp.2931 - 2940 | - |
dc.relation.isPartOf | HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK | - |
dc.citation.title | HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK | - |
dc.citation.volume | 42 | - |
dc.citation.number | 10 | - |
dc.citation.startPage | 2931 | - |
dc.citation.endPage | 2940 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Otorhinolaryngology | - |
dc.relation.journalResearchArea | Surgery | - |
dc.relation.journalWebOfScienceCategory | Otorhinolaryngology | - |
dc.relation.journalWebOfScienceCategory | Surgery | - |
dc.subject.keywordPlus | RECURRENT LARYNGEAL NERVE | - |
dc.subject.keywordPlus | ENERGY-BASED DEVICES | - |
dc.subject.keywordPlus | HARMONIC SCALPEL | - |
dc.subject.keywordPlus | THERMAL-INJURY | - |
dc.subject.keywordPlus | MECHANISMS | - |
dc.subject.keywordPlus | FOCUS | - |
dc.subject.keywordAuthor | continuous intraoperative neuromonitoring | - |
dc.subject.keywordAuthor | ferromagnetic device | - |
dc.subject.keywordAuthor | nerve thermal injury | - |
dc.subject.keywordAuthor | recurrent laryngeal nerve | - |
dc.subject.keywordAuthor | thyroid surgery | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.