Improving the Reliability of Pharmacokinetic Parameters at Dynamic Contrast-enhanced MRI in Astrocytomas: A Deep Learning Approach
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Choi, Kyu Sung | - |
dc.contributor.author | You, Sung-Hye | - |
dc.contributor.author | Han, Yoseob | - |
dc.contributor.author | Ye, Jong Chul | - |
dc.contributor.author | Jeong, Bumseok | - |
dc.contributor.author | Choi, Seung Hong | - |
dc.date.accessioned | 2021-08-30T13:54:57Z | - |
dc.date.available | 2021-08-30T13:54:57Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2020-10 | - |
dc.identifier.issn | 0033-8419 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/53080 | - |
dc.description.abstract | Background: Pharmacokinetic (PK) parameters obtained from dynamic contrast agent-enhanced (DCE) MRI evaluates the microcirculation permeability of astrocytomas, but the unreliability from arterial input function (AIF) remains a challenge. Purpose: To develop a deep learning model that improves the reliability of AIF for DCE MRI and to validate the reliability and diagnostic performance of PK parameters by using improved AIF in grading astrocytomas. Materials and Methods: This retrospective study included 386 patients (mean age, 52 years +/- 16 [standard deviation]; 226 men) with astrocytomas diagnosed with histopathologic analysis who underwent dynamic susceptibility contrast (DSC)-enhanced and DCE MRI preoperatively from April 2010 to January 2018. The AIF was obtained from each sequence: AIF obtained from DSC-enhanced MRI (AIF(DSC)) and AIF measured at DCE MRI (AIF(DCE)). The model was trained to translate AIF(DCE) into AIF(DSC), and after training, outputted neural-network-generated AIF (AIF(generated DSC)) with input AIF DCE. By using the three different AIFs, volume transfer constant (K-trans), fractional volume of extravascular extracellular space (V-e), and vascular plasma space (V-p) were averaged from the tumor areas in the DCE MRI. To validate the model, intraclass correlation coefficients and areas under the receiver operating characteristic curve (AUCs) of the PK parameters in grading astrocytomas were compared by using different AIFs. Results: The AIF-generated, DSC-derived PK parameters showed higher AUCs in grading astrocytomas than those derived from AIF(DCE) (mean K-trans, 0.88 [95% confidence interval {CI}: 0.81, 0.93] vs 0.72 [95% CI: 0.63, 0.79], P = .04; mean V-e, 0.87 [95% CI: 0.79, 0.92] vs 0.70 [95% CI: 0.61, 0.77], P = .049, respectively). K-trans and V-e showed higher intraclass correlation coefficients for AIF(generated DSC) than for AIF(DCE) (0.91 vs 0.38, P < .001; and 0.86 vs 0.60, P < .001, respectively). In AIF analysis, baseline signal intensity (SI), maximal SI, and wash-in slope showed higher intraclass correlation coefficients with AIF(generated DSC) than AIF(DCE) (0.77 vs 0.29, P < .001; 0.68 vs 0.42, P = .003; and 0.66 vs 0.45, P = .01, respectively. Conclusion: A deep learning algorithm improved both reliability and diagnostic performance of MRI pharmacokinetic parameters for differentiating astrocytoma grades. (C) RSNA, 2020 | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | RADIOLOGICAL SOC NORTH AMERICA | - |
dc.subject | ARTERIAL INPUT FUNCTION | - |
dc.subject | DIFFERENTIATION | - |
dc.subject | NOISE | - |
dc.title | Improving the Reliability of Pharmacokinetic Parameters at Dynamic Contrast-enhanced MRI in Astrocytomas: A Deep Learning Approach | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | You, Sung-Hye | - |
dc.identifier.doi | 10.1148/radiol.2020192763 | - |
dc.identifier.scopusid | 2-s2.0-85091470206 | - |
dc.identifier.wosid | 000574262800042 | - |
dc.identifier.bibliographicCitation | RADIOLOGY, v.297, no.1, pp.178 - 188 | - |
dc.relation.isPartOf | RADIOLOGY | - |
dc.citation.title | RADIOLOGY | - |
dc.citation.volume | 297 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 178 | - |
dc.citation.endPage | 188 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | ARTERIAL INPUT FUNCTION | - |
dc.subject.keywordPlus | DIFFERENTIATION | - |
dc.subject.keywordPlus | NOISE | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.