Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Effects of blood flow on the antibacterial efficacy of chlorhexidine and silver sulfadiazine coated central venous catheter A simulation-based pilot study

Full metadata record
DC Field Value Language
dc.contributor.authorCui, Yong Huan-
dc.contributor.authorChoi, Yoon Ji-
dc.contributor.authorKim, Eung Hwi-
dc.contributor.authorYu, Joon Ho-
dc.contributor.authorSeong, Hyun Young-
dc.contributor.authorChoi, Sung-uk-
dc.contributor.authorYoon, Seung Zhoo-
dc.contributor.authorHuh, Hyub-
dc.date.accessioned2021-08-30T13:58:57Z-
dc.date.available2021-08-30T13:58:57Z-
dc.date.created2021-06-18-
dc.date.issued2020-09-25-
dc.identifier.issn0025-7974-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/53109-
dc.description.abstractBackground: Chlorhexidine and silver sulfadiazine coated central venous catheters (CSS-CVC) may cause loss of antimicrobial efficacy due to friction between the CVC surface and sheer stress caused by the blood flow. Therefore, the aim of this study was to investigate the antibacterial efficacy of CSS-CVC at various flow rates using a bloodstream model. Methods: Each CVC was subjected to various flow rates (0.5, 1, 2, and 4 L/min) and wear-out times (0, 24, 48, 72, 96, and 120 hours), and the optical density (OD) 600 after aStaphylococcus aureusincubation test was used to determine the antibacterial effect of CSS-CVC. Results: In the 0.5 L/min group, there was no significant change in the OD600 value up to 120 hours compared with the baseline OD600 value for CSS-CVC (P > .467). However, the OD600 values of CSS-CVC in the 1 L/min (P < .001) and 2 L/min (P < .001) groups were significantly reduced up to 72 hours, while that in the 4 L/min (p < 0.001) group decreased rapidly up to 48 hours. Conclusion: This study suggests that there is a doubt whether sufficient antibacterial function can be maintained with prolonged duration of catheter placement.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherLIPPINCOTT WILLIAMS & WILKINS-
dc.subjectSTREAM INFECTION-
dc.subjectPREVENTION-
dc.titleEffects of blood flow on the antibacterial efficacy of chlorhexidine and silver sulfadiazine coated central venous catheter A simulation-based pilot study-
dc.typeArticle-
dc.contributor.affiliatedAuthorChoi, Yoon Ji-
dc.contributor.affiliatedAuthorYoon, Seung Zhoo-
dc.identifier.doi10.1097/MD.0000000000022218-
dc.identifier.scopusid2-s2.0-85092527757-
dc.identifier.wosid000579445400016-
dc.identifier.bibliographicCitationMEDICINE, v.99, no.39-
dc.relation.isPartOfMEDICINE-
dc.citation.titleMEDICINE-
dc.citation.volume99-
dc.citation.number39-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalWebOfScienceCategoryMedicine, General & Internal-
dc.subject.keywordPlusSTREAM INFECTION-
dc.subject.keywordPlusPREVENTION-
dc.subject.keywordAuthorantibacterial activity-
dc.subject.keywordAuthorbloodstream model-
dc.subject.keywordAuthorcatheter-related bloodstream infection-
dc.subject.keywordAuthorcentral venous catheters-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Seung Zhoo photo

Yoon, Seung Zhoo
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE