Error Correction Regression Framework for Enhancing the Decoding Accuracies of Ear-EEG Brain-Computer Interfaces
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kwak, No-Sang | - |
dc.contributor.author | Lee, Seong-Whan | - |
dc.date.accessioned | 2021-08-30T18:04:21Z | - |
dc.date.available | 2021-08-30T18:04:21Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2020-08 | - |
dc.identifier.issn | 2168-2267 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/53867 | - |
dc.description.abstract | Ear-electroencephalography (EEG) is a promising tool for practical brain-computer interface (BCI) applications because it is more unobtrusive, comfortable, and mobile than a typical scalp-EEG system. However, an ear-EEG has a natural constraint of electrode location (e.g., limited in or around the ear) for acquiring informative brain signals sufficiently. Achieving reliable performance of ear-EEG in specific BCI paradigms that do not utilize brain signals on the temporal lobe around the ear is difficult. For example, steady-state visual evoked potentials (SSVEPs), which are mainly generated in the occipital area, have a significantly attenuated and distorted amplitude in ear-EEG. Therefore, preserving the high level of decoding accuracy is challenging and essential for SSVEP BCI based on ear-EEG. In this paper, we first investigate linear and nonlinear regression methods to increase the decoding accuracy of ear-EEG regarding SSVEP paradigm by utilizing the estimated target EEG signals on the occipital area. Then, we investigate an ensemble method to consider the prediction variability of the regression methods. Finally, we propose an error correction regression (ECR) framework to reduce the prediction errors by adding an additional nonlinear regression process (i.e., kernel ridge regression). We evaluate the ECR framework in terms of single session, session-to-session transfer, and subject-transfer decoding. We also validate the online decoding ability of the proposed framework with a short-time window size. The average accuracies are observed to be 91.11 +/- 9.14%, 90.52 +/- 8.67%, 86.96 +/- 12.13%, and 78.79 +/- 12.59%. This paper demonstrates that SSVEP BCI based on ear-EEG can achieve reliable performance with the proposed ECR framework. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
dc.subject | EVOKED-POTENTIALS | - |
dc.subject | MOTOR IMAGERY | - |
dc.subject | CLASSIFICATION | - |
dc.subject | SIGNALS | - |
dc.subject | BCI | - |
dc.subject | MEG | - |
dc.title | Error Correction Regression Framework for Enhancing the Decoding Accuracies of Ear-EEG Brain-Computer Interfaces | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Seong-Whan | - |
dc.identifier.doi | 10.1109/TCYB.2019.2924237 | - |
dc.identifier.scopusid | 2-s2.0-85088202458 | - |
dc.identifier.wosid | 000548811800020 | - |
dc.identifier.bibliographicCitation | IEEE TRANSACTIONS ON CYBERNETICS, v.50, no.8, pp.3654 - 3667 | - |
dc.relation.isPartOf | IEEE TRANSACTIONS ON CYBERNETICS | - |
dc.citation.title | IEEE TRANSACTIONS ON CYBERNETICS | - |
dc.citation.volume | 50 | - |
dc.citation.number | 8 | - |
dc.citation.startPage | 3654 | - |
dc.citation.endPage | 3667 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Automation & Control Systems | - |
dc.relation.journalResearchArea | Computer Science | - |
dc.relation.journalWebOfScienceCategory | Automation & Control Systems | - |
dc.relation.journalWebOfScienceCategory | Computer Science, Artificial Intelligence | - |
dc.relation.journalWebOfScienceCategory | Computer Science, Cybernetics | - |
dc.subject.keywordPlus | EVOKED-POTENTIALS | - |
dc.subject.keywordPlus | MOTOR IMAGERY | - |
dc.subject.keywordPlus | CLASSIFICATION | - |
dc.subject.keywordPlus | SIGNALS | - |
dc.subject.keywordPlus | BCI | - |
dc.subject.keywordPlus | MEG | - |
dc.subject.keywordAuthor | Electroencephalography | - |
dc.subject.keywordAuthor | Decoding | - |
dc.subject.keywordAuthor | Visualization | - |
dc.subject.keywordAuthor | Electrodes | - |
dc.subject.keywordAuthor | Ear | - |
dc.subject.keywordAuthor | Estimation | - |
dc.subject.keywordAuthor | Brain modeling | - |
dc.subject.keywordAuthor | Brain-computer interface (BCI) | - |
dc.subject.keywordAuthor | ear-electroencephalography (EEG) | - |
dc.subject.keywordAuthor | nonlinear regression | - |
dc.subject.keywordAuthor | steady-state visual evoked potential (SSVEP) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.