Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of Optical Coherence Tomography Findings and Histological Findings of Meibomian Gland in Rats

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Seung Hoon-
dc.contributor.authorEom, Youngsub-
dc.contributor.authorSong, Jong Suk-
dc.contributor.authorNa, Kyung Sun-
dc.contributor.authorKim, Eun Chul-
dc.contributor.authorKim, Hyun Seung-
dc.contributor.authorKim, Man Soo-
dc.contributor.authorHwang, Ho Sik-
dc.date.accessioned2021-08-30T18:44:50Z-
dc.date.available2021-08-30T18:44:50Z-
dc.date.created2021-06-18-
dc.date.issued2020-08-
dc.identifier.issn0378-6471-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/54268-
dc.description.abstractPurpose: To compare optical coherence tomography (OCT) and histological findings of Meibomian glands in rats. Based on these results, the histological findings of the structures seen using OCT were clarified. Methods: En bloc excision was performed on the upper and lower eyelids in two rats. The axis of the Meibomian gland was vertically scanned with three-dimensional (3D) OCT and reconstructed into 3D images. The samples were fixed in 10% formalin again and stained with hematoxylin and eosin. The findings of the OCT and histological examinations were then compared to determine the histological characteristics of the structures observed in the OCT. Results: The surface of the acinus was well-delineated in the Meibomian glands of rats using OCT. However, no deep acini were observed in the central ducts. Conclusions: The structure of Meibomian glands imaged by OCT in rats was limited to the surface of the acinus. The structure of the reconstructed Meibomian gland ex vivo was similar to that of the human Meibomian gland. The possibility of developing an in vivo meibography system was therefore confirmed in animals.-
dc.languageKorean-
dc.language.isoko-
dc.publisherKOREAN OPHTHALMOLOGICAL SOC-
dc.subjectDRY EYE-
dc.subjectMEIBOGRAPHY-
dc.subjectDYSFUNCTION-
dc.titleComparison of Optical Coherence Tomography Findings and Histological Findings of Meibomian Gland in Rats-
dc.typeArticle-
dc.contributor.affiliatedAuthorSong, Jong Suk-
dc.identifier.doi10.3341/jkos.2020.61.8.849-
dc.identifier.scopusid2-s2.0-85092311895-
dc.identifier.wosid000573966200001-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, v.61, no.8, pp.849 - 854-
dc.relation.isPartOfJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY-
dc.citation.titleJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY-
dc.citation.volume61-
dc.citation.number8-
dc.citation.startPage849-
dc.citation.endPage854-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART002613710-
dc.description.journalClass1-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaOphthalmology-
dc.relation.journalWebOfScienceCategoryOphthalmology-
dc.subject.keywordPlusDRY EYE-
dc.subject.keywordPlusMEIBOGRAPHY-
dc.subject.keywordPlusDYSFUNCTION-
dc.subject.keywordAuthorHistology-
dc.subject.keywordAuthorMeibography-
dc.subject.keywordAuthorMeibomian gland-
dc.subject.keywordAuthorOptical coherence tomography-
dc.subject.keywordAuthorRat-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Song, Jong Suk photo

Song, Jong Suk
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE