Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Factors for good near and distance visual outcomes of multifocal intraocular lens with inferior segmental near add

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Jung Wan-
dc.contributor.authorEom, Youngsub-
dc.contributor.authorChung, Hyun Woo-
dc.contributor.authorSong, Jong Suk-
dc.contributor.authorJeong, Ji Won-
dc.contributor.authorPark, Seh Kwang-
dc.contributor.authorKim, Hyo Myung-
dc.date.accessioned2021-08-30T18:48:12Z-
dc.date.available2021-08-30T18:48:12Z-
dc.date.created2021-06-18-
dc.date.issued2020-08-
dc.identifier.issn0721-832X-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/54298-
dc.description.abstractPurpose This study was conducted to investigate factors related to postoperative good near and distance visual outcomes in the Lentis Mplus LS-313 MF20 (Oculentis Gmbh, Berlin, Germany) intraocular lens (IOL)-implanted eye. Methods A retrospective cross-sectional study analyzed a total of 198 eyes of 198 patients. Patients with 20/20-or-more uncorrected distance visual acuity (UDVA, 5 m) and J2-or-more uncorrected near visual acuity (UNVA, 40 cm) were distributed into the good visual outcome (GVO) group (n = 96), and the remaining patients were distributed into the moderate visual outcome (MVO) group (n = 102). Differences between the two groups were compared for patient age, preoperative measurements (kappa distance, kappa angle, and pupil size), and postoperative measurements (residual sphere, cylinder, and spherical equivalent) to explore factors related to good visual outcomes after IOL implantation. Results The average age of the GVO group (56.2 years) was significantly lower than that of the MVO group (58.6 years), and the average kappa distance of the former was significantly smaller than that of the latter. However, there were no significant differences between the two groups in kappa angle and pupil size. Notably, multivariate binary regression analysis revealed that multiple factors including age, residual cylinder, and spherical equivalent were associated with good visual outcomes. Based on the receiver operating characteristic curve, cutoff values regarded as good visual outcome following cataract surgery were calculated to be - 0.38 CD in residual cylinder and - 0.32 D in residual spherical equivalent. Conclusions Patients with implanted Lentis Mplus LS-313 MF20 IOL who are young, had small kappa distance, and had low levels of postoperative residual cylinder and spherical equivalent tended to exhibit good vision at both near and distance. These results imply that surgeons should minimize postoperative residual cylinder and spherical equivalent to provide good visual outcomes to patients with implanted Lentis Mplus LS-313 MF20 IOL.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherSPRINGER-
dc.subjectCAPSULAR TENSION RING-
dc.subjectOPTICAL-PERFORMANCE-
dc.subjectIMPLANTATION-
dc.subjectIMPACT-
dc.subjectPOWER-
dc.titleFactors for good near and distance visual outcomes of multifocal intraocular lens with inferior segmental near add-
dc.typeArticle-
dc.contributor.affiliatedAuthorEom, Youngsub-
dc.contributor.affiliatedAuthorSong, Jong Suk-
dc.contributor.affiliatedAuthorKim, Hyo Myung-
dc.identifier.doi10.1007/s00417-020-04761-1-
dc.identifier.scopusid2-s2.0-85085752633-
dc.identifier.wosid000551176400020-
dc.identifier.bibliographicCitationGRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, v.258, no.8, pp.1735 - 1743-
dc.relation.isPartOfGRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY-
dc.citation.titleGRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY-
dc.citation.volume258-
dc.citation.number8-
dc.citation.startPage1735-
dc.citation.endPage1743-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOphthalmology-
dc.relation.journalWebOfScienceCategoryOphthalmology-
dc.subject.keywordPlusCAPSULAR TENSION RING-
dc.subject.keywordPlusOPTICAL-PERFORMANCE-
dc.subject.keywordPlusIMPLANTATION-
dc.subject.keywordPlusIMPACT-
dc.subject.keywordPlusPOWER-
dc.subject.keywordAuthorVisual outcomes-
dc.subject.keywordAuthorRefractive-
dc.subject.keywordAuthorMultifocal-
dc.subject.keywordAuthorIntraocular lens-
dc.subject.keywordAuthorKappa distance-
dc.subject.keywordAuthorResidual refractive error-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Song, Jong Suk photo

Song, Jong Suk
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE